E04: Fluid Temperature Sensor (Fts) Or Thermocouple Disconnected; E05: Circuit Board Overheated; E06: Communication Cable Unplugged - Graco Reactor H-VR Repair And Parts Manual

Variable ratio hydraulic proportioner
Hide thumbs Also See for Reactor H-VR:
Table of Contents

Advertisement

Temperature Control Diagnostic Codes
E04: Fluid Temperature Sensor
(FTS) or thermocouple
disconnected
1. Check temperature sensor connections to long
green connector (B) on temperature control module,
page 35. Unplug and re-plug sensor wires.
2. Test fluid temperature sensor continuity with ohm-
meter, page 10.
3. If an error occurred for the hose zone, check FTS
connections at each section of hose.
4. If an error occurred for the hose zone, test FTS by
plugging directly into machine.
F
5. To verify heater control module is not causing the
problem, use a wire to short-circuit the two pins cor-
responding to the FTS (red and yellow for A or B
zone, red and purple for hose). The display will
show the control heater module temperature.
6. If an error occurred for the hose zone, temporarily
use the current control mode. Refer to Reactor
H-VR Operation manual 313539.
12

E05: Circuit board overheated

NOTE: Each module has an on-board temperature
sensor. Heat is turned off if module temperature
exceeds 185°F (85°C) within the heater module.
1. Check that fan above electrical cabinet is operating.
2. Check that electrical cabinet door is properly
installed.
3. Check for obstructions blocking cooling holes in bot-
tom of electrical cabinet.
4. Clean heatsink fins behind heater control modules.
5. Ambient temperature may be too high. Allow Reac-
tor to cool by moving to a cooler location.
E06: Communication cable
unplugged
1. Unplug and re-plug cable that connects heater con-
ti9878a
trol module to heater module.
2. Replace communication cable if problem persists.
313540L

Advertisement

Table of Contents
loading

Table of Contents