E27: High Motor Temperature - Graco Reactor H-VR Repair And Parts Manual

Variable ratio hydraulic proportioner
Hide thumbs Also See for Reactor H-VR:
Table of Contents

Advertisement

4. To test if the failure is with the transducer or the
socket on the motor control board:
a. Reverse connections at J3 and J8 on the motor
control board.
b. Run the unit until pressure is 1000-1500 psi
(7-10.5 MPa, 70-105 bar).
c. If the problem stays on the same side as before,
replace the motor control board. If the problem
appears to move to the other side, replace the
transducer.
If the gauge readings are not very close:
1. Secure bleed lines in grounded waste containers, or
route back to respective component A or B supply
drum. Reduce pressure of higher component by
slightly turning PRESSURE RELIEF/SPRAY valve
for that component toward PRESSURE
RELIEF/CIRCULATION
balanced pressures.
NOTE: Turn PRESSURE RELIEF/SPRAY valve only
enough to balance pressure. If you turn it com-
pletely, all pressure will bleed off.
2. If you cannot get the pressures to balance:
a. Check for damaged pump seals or check
valves.
b. Check if you've run out of material.
c. Check for a plugged fluid path by using the feed
pump to push fluid through the gun manifold.
3. If you are able to balance pressures, try running the
unit.
4. If a fast E24 error occurs again, and the gauges
readings are not very close:
313540L
, until gauges show
Turn valve slightly
1
to reduce pressure
of higher
1
ti9877a
a. Check and clean the gun inlet screens.
b. Check and clean the gun mix chamber impinge-
ment ports and center port. See gun manual.
NOTE: Some mix chambers have counter bored
impingement ports, requiring two drill sizes to clean
completely.
Slow E24 Errors
Slow E24 errors occur gradually. The pressures are bal-
anced when you begin spraying, but slowly become
imbalanced until an E24 occurs.
NOTE: If spraying at a ratio other than 1:1, an E24
may occur. Size hoses and mix chamber appropri-
ately to avoid pressure imbalance.
Causes of Slow E24 Errors
one side of the gun is partially plugged.
the A or B proportioner pump has failed.
the A or B feed pump has failed.
the A or B feed pump pressure is set too high.
the hose is not heating properly.
kinked supply hose.
bottom of drum is damaged, causing blockage of
feed pump inlet.
drum is not vented.

E27: High motor temperature

Causes of E27 Errors
Motor temperature is too high. Reduce pressure,
gun tip size, or move Reactor to a cooler location.
Allow 1 hour for cooling.
Make sure there is no obstruction to fan airflow.
Ensure that the motor/fan shroud is installed.
Check that the motor overtemperature wire assem-
bly is plugged into J9 on the motor control board,
page 34.
If the preceding checks do not correct the problem,
perform the following tests:
1. Turn main power OFF
Motor Control Diagnostic Codes
.
15