8. HLZ Series Operator Troubleshooting
The HLZ does not
function properly.
Press the ON/OFF
switch.
Does the
No
computer power
up?
Yes
Computer is
functioning.
Does air blow
out of the cowl
assembly?
Yes
The blower is
operational.
Run the unit for 20 minutes
before continuing with
troubleshooting.
Observe the
computer display.
Go to next page and
continue at the top of
the flow chart.
Frymaster L.L.C., 8700 Line Avenue 71106, P.O. Box 51000, Shreveport, Louisiana 71135-1000
Printed in the United States
The blower, latching
No
relay, or solid state
relays need service.
318-865-1711
Is the power cord
Yes
plugged into the proper
voltage outlet?
No
Plug power cord
into proper outlet.
Press ON/OFF
switch once.
Does the
Yes
computer come
on?
No
Low voltage
transformer, fuse, or
computer is faulty.
Call your authorized
Frymaster servicer.
FAX 318-862-2394
Service Hotline
1-800-24-FRYER
Return to Cover
Check wall circuit
breaker to see if it
has tripped.
If circuit breaker
has tripped, reset
the breaker.