Installation Procedures
13. Connect harnesses to Platform Ramp Circuit Board
Connect the communications cable to COMM. Connect the Black/Green wire to 'BATT+'.
Connect the ground wire to 'BATT‐'.
Connect the
ground wire
to BATT-
Connect the
black/green
wire to BATT+
14. If necessary, loosen leveling bolts on the back side of
the platform.
Loosen the jam nut on each and turn the bolts
in or out to position the platform.
When empty, the edge farthest away from the chassis
should be slightly (1/2" – 3/4") higher to compensate for the
deflection when fully loaded with a passenger and chair.
15. Plug the harness on the shroud
the top of the platform mount. Route the two ramp cables
through the two slots on either side of the shroud then secure
the shroud with the four screws on the sides.
8
[Figure 8-1]
Figure 8-1
[Figure 8-2]
into the harness at
| www.harmar.com | 800-833-0478
Figure 8-1
[Figure 8-1]
TEC0029 2016SEPT12 PN: 630-00001 REV C
Connect the
communications
cable to COMM
Figure 8-2
Figure 8-3