2.4.2 Memory Button - AEMC 3910 User Manual

True rms power meter
Table of Contents

Advertisement

The Model 3910 stores all the measurements present when peak is
selected. The first four measurements (V, A, W, PF) are displayed on page
1 and the following three measurements (Var, VA, Hz) on page 2 (press
the PAGE button). For example, you can find the voltage, the power, etc.,
at the moment when current is at a peak.
In PEAK mode, the typical acquisition time is 400ms. Each new peak is
taken into account as long as the PEAK button is activated. To exit PEAK
mode, press the PEAK button.
2.4.2 Memory Button
This button has two functions:
• First Function - Memory
• Second Function - Differential Measurements
Once the values are memorized (MEM is displayed), press the PAGE
button. Page 2 will display the differences between the values in memory
and the values that the instrument continues to measure.

To store page 1 of the display, press the MEM button
once. "MEM" will show on the display.
Voltage, current, active power and power factor are
stored.
Measurements of differences in voltage, current
and active power.
NOTE: The power factor is no longer displayed.
If the difference between measurements is a nega-
tive value, a minus "-" sign is displayed.
To exit memory mode, press the MEM button again.
TRMS Power Meter Model 3910

Advertisement

Table of Contents
loading

Table of Contents