Extron electronics MLC 104 IP Plus Series User Manual page 111

Hide thumbs Also See for MLC 104 IP Plus Series:
Table of Contents

Advertisement

Command/Response Table for Special Function SIS Commands (continued)
Command
Each control module (IRCM, ACM, RCM, CM) has 20 memory blocks reserved for it, no matter how many buttons
are physically present on the module:
• module 1: blocks 26-45
• module 2: blocks 46-65
Memory block numbers are sequential from left to right, top row to bottom row, as shown below.
Button/Switch Memory Block Numbering for Control Modules (IRCMs, ACMs, RCMs, CMs)
Memory Block Numbering
for Any Control Module
with Black Buttons
(Example is for Control Module 1)
26 27 28 29 30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
Buttons and memory blocks are
numbered in a grid of 5 columns
and 4 rows of buttons on each
module, as on the CM-20BB,
shown above.
Memory Block Numbering
for Control Modules with
Clear, Backlit Buttons
CM-3BLB
CM-3BLB
26 27 28
29
30
31
32
33
34
CM-9BLB
ASCII
Response
Command
(MLC to host)
(host to MLC)
• module 3: blocks 66-85
• module 4: blocks 86-105
Memory Block Numbering Examples
RCM-SC with DIP switch set for address 2 (module 3)
SCREEN POSITION
DOWN
STOP
66
68
30
IRCM-DV+ with DIP switch set for addresses 0 and 1 (modules 1 and 2)
35
DVD & VCR CONTROL
Tx
40
29
DVD
VCR
TITLE
MENU
45
31
32
33
TUNER
ENTER
TV/VCR
36
37
39
PREV/REW
PLAY NEXT/FWD PAUSE
41
42
43
44
DVD Half (module 1)
DVD & VCR CONTROL
Tx
49
DVD
VCR
TITLE
MENU
51
52
53
TUNER
ENTER
TV/VCR
56
57
59
PREV/REW
PLAY NEXT/FWD PAUSE
61
62
63
64
VCR Half (module 2)
CM-3BLB
Backlit button modules feature a
grid of 3 columns and 1 or 3 rows of
buttons, as shown at left.
NOTE:
There are still 20 memory
blocks for each module.
• Module 1: memory blocks 26-45.
• Module 2: memory blocks 46-65.
• Module 3: memory blocks 66-85.
• Module 4: memory blocks 86-105.
CM-9BLB
MLC 104 IP Plus Series • SIS
X?
values
and additional descriptions
for Modules with Black Buttons
UP
Module 3 has
70
memory blocks 66-85.
35
Module 1 has
memory blocks 26-45.
STOP
45
55
Module 2 has
memory blocks 46-65.
STOP
65
CM-3BLB, DIP switch set for address 3 (module 4)
86
87
88
CM-3BLB
86
87
88
89
90
91
92
93
94
104
105
Programming and Control
66
67
68
69
70
71
72 73 74 75
76 77 78 79
80
81
82 83 84
85
26
27
28
29
30
31
32 33
34
35
36 37
38
39
40
41
42 43 44
45
46
47
48
49
50
51
52 53
54
55
56 57
58
59
60
61
62 63 64
65
Module 4
has memory
blocks
86-105.
103

Advertisement

Table of Contents
loading

Table of Contents