System Administration; System Administration Login Page - Motorola PTP 300 Series User Manual

Motowi4 series
Hide thumbs Also See for PTP 300 Series:
Table of Contents

Advertisement

Web Page Reference
Link Capacity: The maximum aggregate data rate capacity available for user traffic, assuming
the units have been connected using Fast (100 Mbps) Ethernet. The link capacity is variable
and depends of the prevailing wireless conditions as well as the distance (range) between the two
wireless units.
Transmit Modulation Mode: The modulation mode currently being used on the transmit
channel. List of all the modulation modes can be found in
Section 14
where data rate calculations
plots are given for each available modulation mode.
Receive Modulation Mode: The modulation mode currently being used on the receive channel.
List of all the modulation modes can be found in
Section 14
where data rate calculations plots
are given for each available modulation mode.
Receive Modulation Mode Detail: This supplies the user with information regarding the
receive modulation mode in use. Possible values are:
• Running at maximum receive mode
• Running at user-configured Max Modulation Mode
• Restricted due to byte errors on the wireless link or local Ethernet Tx Fifo Drops
• Restricted because a DFS channel change is in progress
• Restricted due to telecoms acquisition mode
• Restricted due to the low Ethernet link speed
• Limited by the wireless conditions
10
Range: The range
between the 300 Series bridge ODUs. The range is automatically set by the
PTP 300 Series during installation.
8.3 System Administration Pages
The following menu options are available for the system administrator and can be password pro-
tected.
Figure 29
shows the system administration login page. By default a system administrator
password is not set. Simply click the login button to access the system administration features.
Figure 29 System Administration Login Page
Once the password has been set using the 'Change Password' menu item the system administration
pages will only be available after the user has entered the correct password.
10
The PTP 300 Series Bridge displays range in km by default, if the user would prefer to display range using Miles the
'Distance Units' attribute should be set to imperial, see the "Properties" web page
Section 8.3.14
"Properties".