3.8 Flow Sensor Alignment

Warning. When inserting or removing the flow sensor suitable restraining equipment must be used to
prevent the flow sensor being forced out under pressure. Ensure that the valve is fully open.
Note. Safety restraint omitted for clarity.
1
3
Fig. 3.12 Flow Sensor Alignment
OI/FEA100/200–EN Rev. D
2
See Note
Referring to Fig. 3.12:
a Slacken the nut.
b Align parallel to the pipe (within 2°) –
measurement error due to misalignment
(of <2) is <0.15 %.
c Tighten to 40 Nm (30 ft lbf).