AquaProbe FEA100 / FEA200
Electromagnetic flowmeter – insertion-type flow sensors
6 Specification
FEA100/FEA200 Flow Sensor
Maximum insertion length
300mm (12 in.)
500mm (20 in.)
700mm (25 in.)
1000mm (40 in.)
Pipe sizes
200 to 8000 mm (8 to 320 in.) nominal bore
Protection
IP68/NEMA 6P (Indefinite submersion down to 10 m [30 ft.])
Weight
<3.5kg (7.7 lb)
Accuracy
Velocity
±2% of Rate or ±2mm/s (±0.08 in./s) whichever is the greater
Volume
Refer to ISO 7145-1982 (BS 1042 section 2.2) for details
Flow condition
Fully developed profile in accordance with
ISO 7145-1982 (BS1042 section 2.2.)
Pressure limitations
20 bar (295 psi)
Max. Pressure
20 bar (295 PSI)
Pressure equipment Directive 97/23/EC
This product is applicable in networks for the supply, distribution and discharge of water and associated equipment and
is therefore exempt
Conductivity
>50µS/cm
Connections
1 in. BSP
1 in. NPT
1.5 in. BSP
24
6 Specification
OI/FEA100/200–EN Rev. D