Table Of Contents - ABB AquaProbe FEA100 User Manual

Electromagnetic flowmeter insertion-type flow sensors
Hide thumbs Also See for AquaProbe FEA100:
Table of Contents

Advertisement

AquaProbe FEA100 / FEA200
Electromagnetic flowmeter - insertion-type flow sensors
1
Safety ............................................................................................................................................... 3
1.1
Health & Safety ........................................................................................................................ 3
1.2
Electrical Safety - CEI/IEC 61010-1:2001-2 ............................................................................. 3
1.3
Symbols - CEI/IEC 61010-1:2001-2 ........................................................................................ 3
1.4
Product Recycling Information ((European customers only) ...................................................... 4
1.5
Information on ROHS Directive 2011/65/EU (RoHS II) .............................................................. 5
1.6
Chemical Reagents ................................................................................................................. 5
1.7
Safety Precautions ................................................................................................................... 5
1.8
Safety Conventions .................................................................................................................. 6
1.9
Safety Recommendations ........................................................................................................ 6
1.10 Service and Repairs ................................................................................................................. 6
1.11 Potential Safety Hazards .......................................................................................................... 6
2
System Schematic ........................................................................................................................... 7
3
Mechanical Installation .................................................................................................................... 8
3.1
Location - Environmental Conditions ....................................................................................... 8
3.2
Use .......................................................................................................................................... 9
3.3
Location - Flow Conditions .................................................................................................... 10
3.3.1 International Standard for Flow Measurement .............................................................. 11
3.3.2 Velocity Limitations ...................................................................................................... 11
3.4
Location - Mechanical ........................................................................................................... 13
3.5
Safety .................................................................................................................................... 14
3.6
Installing the Flow Sensor ...................................................................................................... 15
3.7
Setting the Insertion Depth .................................................................................................... 16
3.7.1 Centre Line Method for Pipe Diameters 1 m (40 in.) ................................................. 16
3.7.3 Mean Axial Velocity Method ......................................................................................... 18
3.8
Flow Sensor Alignment .......................................................................................................... 19
4
Electrical Installation ..................................................................................................................... 20
4.1
4.2
Environmental Protection ....................................................................................................... 21
4.3
5
Setting Up ...................................................................................................................................... 22
5.1
Introduction ........................................................................................................................... 22
5.2
Centre Line Method ............................................................................................................... 22
5.3
Mean Axial Velocity Method (1/8 Diameter) ............................................................................ 23
5.4
Partial Velocity Traverse ......................................................................................................... 23
5.5
Transmitter Setup .................................................................................................................. 23
6
Specification .................................................................................................................................. 24
OI/FEA100/200-EN Rev. D
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquaprobe fea200

Table of Contents