Download Print this page
eXact Micro 7+ Instruction Manual

eXact Micro 7+ Instruction Manual

Advanced photometer system pool/spa “splash” kit
Hide thumbs Also See for Micro 7+:

Advertisement

IDEAL FOR TESTING POOLS AND SPAS,
ENVIRONMENTAL, & DRINKING WATER
USEPA, DIN, & ISO Compliant for Free & Total Chlorine Testing
(4500-CL G, DIN Standard 38 408 G4, ISO 7393/2)
USEPA
DIN, ISO
Compliant
Free AND Total
Chlorine
(4500-Cl G, DIN STANDARD
38 408 G4, ISO 7393/2)
Micro 7+ is Manufactured and tested in an ISO
9001 Facility
The eXact
Micro 7+ Advanced
®
Photometer System has been
designed for use with the eXact
Micro reagent delivery system.
Manufactured By: Industrial Test Systems, Inc.
Phone:
www.poolcheckonline.com
© 2010 Industrial T
Micro 7+
Pool/Spa "Splash" Kit
Advanced Photometer System
Strip
®
- INSIDE THE U.S.
- OUTSIDE THE U.S.
Fax:
ITS@SENSAFE.COM
WWW.SENSAFE.COM
is a registered trademark of Industrial T
®
NOTE: No water chlorine treatment
recommendations are included in
this manual. Follow guidelines
supplied by manufacturer or
government regulation.
Index:
Parameter
Free Chlorine (DPD-1)
Total Chlorine (DPD-3)
pH
Total Alkalinity
Calcium Hardness
Copper
Chloride (Salt)
Cyanuric Acid
Iron
Phosphate
About Your Photometer
NOTES
Tips for Best Accuracy
Battery Installation
Warranty (5 year)
Reorder Information
USEPA Compliance
Kit Components
Visit us online at sensafe.com/micro for up-to-date
product information & NEW tests available.
To prevent warranty issues, it is recommended that within
30 days of purchase, you should register your ownership
and include the serial number (on bottom of Micro 7+ Meter)
by going to our website (http://www.sensafe.com/micro).
By registering, you will be updated when needed regarding
the Micro 7+.
Revision 07/26/11
Page
MENU
4
5
6
6
7
7
8
9
10
11
3
12
13
14
14
15
2, 16
16
CL1
CL1
PH2
AL4
CA5
CU6
TR7
TR7
TR7
TR7

Advertisement

loading
Need help?

Need help?

Do you have a question about the Micro 7+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for eXact Micro 7+

  • Page 1 NOTES Tips for Best Accuracy Battery Installation The eXact Micro 7+ Advanced ® Warranty (5 year) Photometer System has been designed for use with the eXact Strip ® Reorder Information Micro reagent delivery system. USEPA Compliance 2, 16 Kit Components Manufactured By: Industrial Test Systems, Inc.
  • Page 2 Strip Micro 7+ has been designed to offer the user a more “Green” and cost-effective alternative to testing. ® Instead of using a 10ml water sample, eXact Strip Micro 7+ uses a 4ml water sample, which uses up to 60% ®...
  • Page 3: Compliance Verification For Free And Total Chlorine Testing

    The algorithms in the software reflect the best correlation of the eXact Micro 7+ Systems against the ® AWWA, US EPA , DIN, and ISO reference test methods for chlorine. Studies show that the eXact Micro ® 7+ System repeatedly agrees with an EPA Compliant reference method greater than 99% (R = 0.9912,...
  • Page 4 DPD reagent. Use this as your Free Chlorine level. DO NOT discard the sample from the Free Chlorine test, if you are planning to run eXact ® Strip Micro DPD-3 (Total Chlorine) Procedure, move directly to steps 8-10 on page 5.
  • Page 5 ® located on the previous page. REMOVE STRIP Remove one (1) eXact Strip Micro CL (DPD-3), Part No. 486638 from the bottle before ® beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately.
  • Page 6: Ph Test Procedure

    Test Procedure REMOVE STRIP Remove one (1) eXact Strip Micro PH, Part No. 486639 from the bottle before ® beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on; the display will show all annunciators, then the current MENU selection, followed by the last reading.
  • Page 7 Calcium Hardness Test Procedure REMOVE STRIP Remove one (1) eXact Strip Micro CA, Part No. 486629 from the bottle before ® beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on;...
  • Page 8 Chloride value of 2760 ppm). Record result. After testing is completed, rinse cell immediately. Chloride Table (as NaCl) Sodium Chloride results require the table below. Follow eXact Micro 7+ Chloride (as NaCl) Test ® Procedure (above) using eXact Strip Micro CHLORIDE, Part No. 481657. NOTE: To convert the NaCl value to ®...
  • Page 9 (parts per million). (Example: a “TR7” result of 75.3 (use only the 75 for the chart) equals a Cyanuric Acid value of 7 ppm). Record result. After testing is completed, rinse cell immediately. Cyanuric Acid Table Cyanuric Acid results require the table below. Follow eXact Micro 7+ Cyanuric Acid Test ®...
  • Page 10 Tilt meter to discard about 0.2mL water in order to leave room for powder reagent. Add the Reagent EZ Open REDUCER, Part No. 486601 to the CELL and cap contents of one eXact ® meter cell with mixing cap. Press READ to start the 20 SECOND countdown timer, place thumb over cap, and mix the sample by turning the meter upside-down repetitively.
  • Page 11 (Example: a “TR7” result of 85.3 (use only the 85 for the chart) equals a Phosphate value of 0.39 ppm). Record result. After testing is completed, rinse cell immediately. Phosphate Table Iron results require the table below. Follow eXact Micro 7+ Phosphate Test Procedure (above) ®...
  • Page 12 ® DIN-compliant meters that are acceptable for compliance reporting. The DPD-1 strips deliver the exact reagents in the specified proportions for Free Chlorine and Total Chlorine DPD Colorimetric determination as required in Standard Methods for the Examination of Water and Wastewater Method 4500-Cl G (published by APHA, AWWA, and WEF): Monobasic Phosphate, Dibasic Phosphate, EDTA Sodium salt, and DPD Sulfate.
  • Page 13 Chlorine and Bromine (Ozone can be measured in CL1 MENU). Be sure the CELL is filled to capacity (4ml), especially for pH and Total Alkalinity. Sample water that may splash out of the CELL during movement of the eXact Strip Micro will not ®...
  • Page 14: Top View

    Registration of your eXact photometer must be received within 30 days from date of purchase to ® activate the warranty. The eXact photometer is warranted to be free from defects in materials and ® workmanship for a period of five (5) years from the date of purchase by the customer. ITS will repair or replace any part of the product which is deemed to be faulty or otherwise defective.
  • Page 15 (486643) test, which is a liquid reagent (SPADNS), and Iron (481623) test, which is a powder reagent. Hydrazine (486649) uses a liquid and strip. If your required procedure is not listed in this manual, please see the back page for our contact information. To ensure optimal performance, store your eXact kit in a cool, dry place away from excess heat (below ®...
  • Page 16: Contact Information

    Micro 7+ Meter in ® ® Menu CL1 and Hach DR890 Colorimeter in Program 9 and Program 12 using Hach powder pillows. ® ® eXact Strip DPD-1 on Hach DR890 and eXact Micro 7 DR890 Micro 7+ 6.00 0.00 0.01 0.04 0.03 0.07...
  • Page 17 Micro 7+ Meter in ® ® Menu CL1 and Hach DR890 Colorimeter in Program 9 and Program 12 using Hach powder pillows. ® ® eXact Strip DPD-1 on Hach DR890 and eXact Micro 7 DR890 Micro 7+ 6.00 0.00 0.01 0.04 0.03 0.07...
  • Page 18 (486643) test, which is a liquid reagent (SPADNS), and Iron (481623) test, which is a powder reagent. Hydrazine (486649) uses a liquid and strip. If your required procedure is not listed in this manual, please see the back page for our contact information. To ensure optimal performance, store your eXact kit in a cool, dry place away from excess heat (below ®...
  • Page 19 7+ ‫ﺭﺳﺎﺋﻞ ﺷﺎﺷﺔ ﻣﻘﻴﺎﺱ ﺇﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ ‫ﺍﻟﺮﺳﺎﺋﻞ ﺍﻷﺗﻴﺔ ﺗﻈﻬﺮ ﻋﻠﻲ ﺍﻟﺸﺎﺷﺔ ﻭﻣﻨﻬﺎ ﺭﺳﺎﺋﻞ ﺍﻷﻋﻄﺎﻝ ﺃﻭ ﺍﻷﺧﻄﺎء. ﺇﺫﺍ ﻇﻬﺮﺕ ﺃﻱ ﺭﺳﺎﻟﺔ ﺃﺧﺮﻱ ﺑﺮﺟﺎء ﺍﻹﺗﺼﺎﻝ ﺑﺨﺪﻣﺔ ﺍﻟﻌﻤﻼء ﺑﺎﻟﻮﻻﻳﺎﺕ‬ .‫ﺍﻟﻤﺘﺤﺪﺓ ﻋﻠﻲ ﺭﻗﻢ 26109233081 ﺍﻟﻘﻢ ﺍﻟﺪﺍﺧﻠﻲ ﺻﻔﺮ‬ ‫ﺍﻹﺻﻼﺡ‬ ‫ﺍﻟﻮﺻﻒ‬ ‫ﺍﻟﺮﺳﺎﻟﺔ‬ DILUTE ‫ﺗﺮﻛﻴﺰ ﺍﻟﻌﻴﻨﺔ ﺃﻋﻠﻲ ﻣﻦ ﻣﺪﻱ ﺍﻹﺧﺘﺒﺎﺭ‬ 487200 ‫ﻭﺃﻋﺪ...
  • Page 20 7+ ‫ﻧﺼﺎﺋﺢ ﻟﺪﻗﺔ ﺍﻟﻨﺘﺎﺋﺞ ﻹﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ .‫ﺇﻗﺮﺃ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﺑﻌﻨﺎﻳﺔ ﻗﺒﻞ ﺍﻹﺳﺘﺨﺪﺍﻡ‬ ‫ﺷﺮﺍﺋﻂ ﺍﻟﺪﻱ ﺑﻲ ﺩﻱ -1,-4 ﺗﻘﺪﻡ ﻋﻴﻨﺎﺕ ﻛﺎﻓﻴﺔ ﻟﻨﺘﺎﺋﺞ ﺩﻗﻴﻘﺔ ﻓﻲ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﻐﺮﻓﺔ ﺍﻟﻌﺎﺩﻳﺔ. ﺇﺫﺍ ﻛﺎﻧﺖ ﺩﺭﺟﺔ‬ ‫ﺣﺮﺍﺭﺓ ﺍﻟﻌﻴﻨﺎﺕ ﺃﻗﻞ ﻣﻦ 01 ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ﻓﺈﻥ ﺍﻝ02 ﺛﺎﻧﻴﺔ ﻟﻐﻤﺲ ﺍﻟﺸﺮﻳﻂ ﺳﺘﻌﻄﻲ ﻧﺘﺎﺋﺞ ﺿﻌﻴﻔﺔ ﻟﻘﻴﻤﺔ ﺍﻟﻜﻠﻮﺭ‬ .‫ﺍﻷﻛﺜﺮ...
  • Page 21 .‫ﺍﻟﺪﺭﺍﺳﺔ ﺗﻮﺿﺢ ﻛﻴﻔﻴﺔ ﺗﻌﺎﻣﻞ ﻛﻞ ﻣﻘﻴﺎﺱ ﻣﻊ ﺍﻟﻤﻌﺎﻳﻴﺮ ﺍﻟﺪﻭﻟﻴﺔ‬ .‫ﻟﺘﻔﺎﺻﻴﻞ ﺃﻛﺜﺮ ﺑﺨﺼﻮﺹ ﻫﺬﻩ ﺍﻟﺪﺭﺍﺳﺔ. ﺑﺮﺟﺎء ﺍﻟﺪﺧﻮﻝ ﻋﻠﻲ ﻣﻮﻗﻌﻨﺎ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ‬ DPD Chlorine Study July 8, 2010 Palintest 9-Way with DPD No.1 Tablet eXact Micro 7+ with ® eXact Strip Micro ®...
  • Page 22 .‫ﺧﻼﻝ ﻫﺬﺍ ﺍﻟﻮﻗﺖ ﺣﺮﻙ ﺍﻟﺴﺆﻳﻂ ﺑﻠﻄﻒ ﻟﻠﺪﺍﺧﻞ ﻭﺍﻟﺨﺎﺭﺝ. ﺛﻢ ﺍﻧﺰﻉ ﺍﻟﺸﺮﻳﻂ ﻋﻨﻤﺎ ﻳﻈﻬﺮ ﺍﻟﺮﻗﻢ )1( ﻋﻠﻲ ﺍﻟﺸﺎﺷﺔ‬ :‫ﺍﺳﺘﺨﺪﻡ ﺍﻟﺠﺪﻭﻝ ﺍﻟﺘﺎﻟﻲ ﻟﻤﻌﺮﻓﺔ ﺗﺮﻛﻴﺰ ﺍﻟﻔﻮﺳﻔﺎﺕ‬ .‫)ﻣﺜﺎﻝ: ﻧﺎﺗﺞ 3.58 ﻳﺴﺎﻭﻱ ﻗﻴﻤﺔ 93.0(. ﺇﻏﺴﻞ ﺍﻟﺨﻠﻴﺔ ﺑﻌﺪ ﺍﻹﺧﺘﺒﺎﺭ‬ Phosphate Table Iron results require the table below. Follow eXact Micro 7+ Phosphate Test Procedure (above) ® using eXact Strip Micro PO , Part No.
  • Page 23 486601 READ 0.00 ZERO/ON READ 0.12 85.3 Total Iron, TPTZ (Fe ) Table Iron results require the table below. eXact Reagent EZ Open REDUCER, Part No. 486601 - for 4mL Samples ® <0.02 <0.02 <0.02 <0.02 <0.02 0.03 0.04 0.05 0.06...
  • Page 24 ‫.ﺍﻷﻳﻤﻦ ﻭﺍﻟﻤﺆﺷﺮﺳﻴﺘﺤﺮﻙ ﻧﺤﻮ ﺍﻟﺸﺎﺷﺔ. ﻣﻌﻠﻨﺎ ﺃﻧﻪ ﻋﻠﻲ ﻭﺷﻚ ﺇﺧﺘﺒﺎﺭ ﺍﻟﻌﻴﻨﺔ‬ :‫ﺍﺳﺘﺨﺪﻡ ﺍﻟﺠﺪﻭﻝ ﺍﻟﺘﺎﻟﻲ ﻟﻤﻌﺮﻓﺔ ﺗﺮﻛﻴﺰ ﺣﻤﺾ ﺍﻟﺴﻴﺎﻧﻮﺭﻳﻚ‬ .‫)ﻣﺜﺎﻝ: ﻧﺎﺗﺞ 3.57 ﻳﺴﺎﻭﻱ ﻗﻴﻤﺔ 7(. ﺇﻏﺴﻞ ﺍﻟﺨﻠﻴﺔ ﺑﻌﺪ ﺍﻹﺧﺘﺒﺎﺭ‬ Cyanuric Acid Table Cyanuric Acid results require the table below. Follow eXact Micro 7+ Cyanuric Acid Test ® Procedure (above) using eXact Reagent CY, Part No.
  • Page 25 .‫)ﻣﺜﺎﻝ: ﻧﺎﺗﺞ 3.56 ﻳﺴﺎﻭﻱ ﻗﻴﻤﺔ 0672(. ﺇﻏﺴﻞ ﺍﻟﺨﻠﻴﺔ ﺑﻌﺪ ﺍﻹﺧﺘﺒﺎﺭ‬ Chloride Table (as NaCl) Sodium Chloride results require the table below. Follow eXact Micro 7+ Chloride (as NaCl) Test ® Procedure (above) using eXact Strip Micro CHLORIDE, Part No. 481657. NOTE: To convert the NaCl value to ®...
  • Page 26 ‫ﺇﺧﺘﺒﺎﺭ ﺻﻼﺑﺔ ﺍﻟﻜﺎﻟﺴﻴﻮﻡ‬ :‫ﺇﻧﺰﻉ ﺍﻟﺸﺮﻳﻂ‬ ‫ ﻣﻜﻮﻥ ﺭﻗﻢ 926684 ﻣﻦ‬eXact Strip Micro CA ‫ﺇﻧﺰﻉ ﻋﺪﺩ 1 ﺷﺮﻳﻂ ﺇﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ ® .‫ﺍﻟﺰﺟﺎﺟﺔ ﻗﺒﻞ ﺍﻹﺧﺘﺒﺎﺭ. ﺿﻊ ﺍﻟﺸﺮﻳﻂ ﻓﻲ ﻣﻜﺎﻥ ﺟﺎﻑ ﻭ ﺇﻏﻠﻖ ﺍﻟﺰﺟﺎﺟﺔ ﻣﺒﺎﺷﺮﺓ‬ :‫ﺷﻐﻞ ﺍﻟﻤﻘﻴﺎﺱ‬ ‫ﺇﺿﻐﻂ ﻋﻠﻲ ﺯﺭ ﺍﻟﺘﺸﻐﻴﻞ‬ ZERO/ON :(CA5) ‫ﺇﺧﺘﺮ ﺍﻹﺧﺘﺒﺎﺭ‬...
  • Page 27 ‫ﺇﺧﺘﺒﺎﺭ ﺍﻟﺮﻗﻢ ﺍﻟﻬﻴﺪﺭﻭﺟﻴﻨﻲ‬ :‫ﺇﻧﺰﻉ ﺍﻟﺸﺮﻳﻂ‬ ‫ ﻣﻜﻮﻥ ﺭﻗﻢ 936684 ﻣﻦ‬eXact Strip Micro pH ‫ﺇﻧﺰﻉ ﻋﺪﺩ 1 ﺷﺮﻳﻂ ﺇﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ ® .‫ﺍﻟﺰﺟﺎﺟﺔ ﻗﺒﻞ ﺍﻹﺧﺘﺒﺎﺭ. ﺿﻊ ﺍﻟﺸﺮﻳﻂ ﻓﻲ ﻣﻜﺎﻥ ﺟﺎﻑ ﻭ ﺇﻏﻠﻖ ﺍﻟﺰﺟﺎﺟﺔ ﻣﺒﺎﺷﺮﺓ‬ :‫ﺷﻐﻞ ﺍﻟﻤﻘﻴﺎﺱ‬ ‫ﺇﺿﻐﻂ ﻋﻠﻲ ﺯﺭ ﺍﻟﺘﺸﻐﻴﻞ‬ ZERO/ON :PH2 ‫ﺇﺧﺘﺮ ﺍﻹﺧﺘﺒﺎﺭ‬...
  • Page 28 DPD-3 :‫ﺍﺧﺘﺒﺎﺭ ﻣﺠﻤﻮﻉ ﺍﻟﻜﻠﻮﺭ‬ .‫ﻣﻠﺤﻮﻇﺔ: ﻫﺬﺍ ﺍﻹﺧﺘﺒﺎﺭ ﻣﺘﺎﺡ ﻓﻘﻂ ﻛﺘﻜﻤﻠﺔ ﻟﻺﺧﺘﺒﺎﺭ ﺍﻟﺴﺎﺑﻖ‬ :‫ﺇﻧﺰﻉ ﺍﻟﺸﺮﻳﻂ‬ 486638 ‫ ﻣﻜﻮﻥ ﺭﻗﻢ‬eXact Strip Micro CL (DPD-3) ‫ﺇﻧﺰﻉ ﻋﺪﺩ 1 ﺷﺮﻳﻂ ﺇﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ ® .‫ﻣﻦ ﺍﻟﺰﺟﺎﺟﺔ ﻗﺒﻞ ﺍﻹﺧﺘﺒﺎﺭ. ﺿﻊ ﺍﻟﺸﺮﻳﻂ ﻓﻲ ﻣﻜﺎﻥ ﺟﺎﻑ ﻭ ﺇﻏﻠﻖ ﺍﻟﺰﺟﺎﺟﺔ ﻣﺒﺎﺷﺮﺓ‬...
  • Page 29 DPD-1 :‫ﺇﺧﺘﺒﺎﺭ ﺍﻟﻜﻠﻮﺭ ﺍﻟﺤﺮ‬ :‫ﺇﻧﺰﻉ ﺍﻟﺸﺮﻳﻂ‬ ‫ﺇﻧﺰﻉ ﻋﺪﺩ 1 ﺷﺮﻳﻂ ﺇﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ ‫ ﻣﻜﻮﻥ ﺭﻗﻢ‬eXact Strip Micro CL (DPD-1) ‫736684 ﻣﻦ ﺍﻟﺰﺟﺎﺟﺔ ﻗﺒﻞ ﺍﻹﺧﺘﺒﺎﺭ. ﺿﻊ ﺍﻟﺸﺮﻳﻂ ﻓﻲ‬ .‫ﻣﻜﺎﻥ ﺟﺎﻑ ﻭ ﺇﻏﻠﻖ ﺍﻟﺰﺟﺎﺟﺔ ﻣﺒﺎﺷﺮﺓ‬ :‫ﺷﻐﻞ ﺍﻟﻤﻘﻴﺎﺱ‬ ‫ﺇﺿﻐﻂ ﻋﻠﻲ ﺯﺭ ﺍﻟﺘﺸﻐﻴﻞ‬ ZERO/ON :(CL1) ‫ﺇﺧﺘﺮ...
  • Page 30 ‫ﺗﻄﺎﺑﻖ ﺇﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﻜﻠﻮﺭ ﺍﻟﺤﺮ ﻭﺍﻟﻜﻠﻮﺭ ﺍﻟﻤﺠﻤﻮﻉ‬ ‫ﻧﻈﺎﻡ ﺇﺧﺘﺒﺎﺭ ﺍﻟﺪﻱ ﺑﻲ ﺩﻱ ﻣﻘﺒﻮﻝ ﻟﺪﻱ ﻣﺨﺘﻠﻒ ﻭﺯﺍﺭﺍﺕ ﺍﻟﺼﺤﺔ ﻭﺍﻟﺒﻴﺌﺔ ﻷﻧﻪ ﻣﻄﺎﺑﻖ ﻟﻤﻮﺍﺻﻔﺎﺕ ﻭﻛﺎﻟﺔ ﺣﻤﺎﻳﺔ ﺍﻟﺒﻴﺌﺔ‬ .‫ﺍﻷﻣﺮﻳﻜﻴﺔ ﻭﺍﻷﻳﺰﻭ ﻭﺍﻟﺪﻳﻦ ﺍﻷﻟﻤﺎﻧﻴﺔ‬ :‫ﺑﺮﺟﺎء ﺍﻹﻃﻼﻉ ﻋﻠﻲ ﺍﻟﺠﺪﻭﻝ ﺍﻟﺘﺎﻟﻲ‬ Component AWWA eXact ® (Free Chlorine) 4500-Cl G DPD-1 1.5% 1.5%...
  • Page 31 7+ ‫ﻣﻮﺍﺻﻔﺎﺕ ﻣﻘﻴﺎﺱ )ﻣﻀﻮﺍء( ﺇﺟﺰﺍﻛﺖ ﻣﺎﻳﻜﺮﻭ‬ ‫ﺍﻟﺸﻜﻞ‬ ‫ﺍﻟﻤﻜﻮﻥ‬ ‫ﻏﻄﺎء ﻟﻠﺨﻠﻂ‬ ‫ﺍﻟﺒﻄﺎﺭﻳﺔ‬ ‫ﺍﻟﺸﺎﺷﺔ‬ ‫ﺯﺭ ﺍﻟﻘﺮﺍءﺓ‬ ‫ﺍﻟﻘﺎﺋﻤﺔ‬ ‫ﺯﺭ ﺍﻟﺘﺸﻐﻴﻞ‬ ‫ﻏﻄﺎء ﺍﻟﺒﻄﺎﺭﻳﺔ‬ (‫ )ﻏﻴﺮ ﻣﺘﺎﺣﺔ‬AAA ‫ﺑﻄﺎﺭﻳﺎﺕ‬ ‫ﻳﺴﺘﺨﺪﻡ ﻹﺧﺘﺒﺎﺭﺍﺕ ﺣﻤﺾ ﺍﻟﺴﻴﺎﻧﻮﺭﻳﻚ‬ ‫.ﻭﺍﻟﻔﻠﻮﺭﻳﺪ ﻭﺍﻟﺤﺪﻳﺪ ﻭﺍﻟﻤﻨﺠﻨﻴﺰ‬ – Measurement Method: Photometric Cell Chamber: Custom-molded, proprietary, PET plastic Light Source: Light Emitting Diode (LED) fused into chamber, non-removable...
  • Page 32 DPD-3 Micro 7+ is Manufactured and tested in an ISO 9001 Facility The eXact Micro 7+ Advanced ® Photometer System has been designed for use with the eXact Strip ® Micro reagent delivery system. 16,2 Industrial Test Systems, Inc. www.sensafe.com/micro...