eXact Well EZ Quick Start Manual

Digital accuracy for reliable water care

Advertisement

Quick Links

Well
ADVANCED PHOTOMETER SYSTEM
DIGITAL ACCURACY FOR RELIABLE WATER CARE
QUICK START GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Well EZ and is the answer not in the manual?

Questions and answers

Summary of Contents for eXact Well EZ

  • Page 1 Well ADVANCED PHOTOMETER SYSTEM DIGITAL ACCURACY FOR RELIABLE WATER CARE QUICK START GUIDE...
  • Page 2: Table Of Contents

    ........WELCOME TO YOUR NEW WELL EXACT ®...
  • Page 3: Well Exact ® Ez Overview

    Part no. 486203 between 15cm and 1m INSTALL “AAA” BATTERIES (NOT INCLUDED) 1. Use a #4 Phillips head screwdriver to remove the screw from the base of your Well eXact EZ . ® 2. Remove the base. 3. Install Four (4) new AAA batteries as illustrated inside your photometer’s battery compartment.
  • Page 4: Fill, Dip, Read Ph

    FILL, DIP, READ POWER ON PHOTOMETER Press the button to power on the Well eXact ® FILL CELL Rinse the cell 3 times with the water sample to FILL be tested and to the top to begin test. Use the included cleaning brush to clean the cell after each test to achieve the most accurate result.
  • Page 5 FILL, DIP, READ REMOVE STRIP Remove one eXact Strip Micro PH and set in a dry, ® convenient place. Replace cap on bottle. DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously the eXact Strip by submerging ®...
  • Page 6 FILL, DIP, READ TOTAL IRON POWER ON PHOTOMETER Press the button to power on the Well eXact ® EZ. Press and re-press the button until the display shows FE2. RINSE AND FILL CELL Clean cell with Distilled Vinegar (5%), or 0.1N HCl before fi...
  • Page 7: Total Iron

    DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all ® pads in the sample then use a gentle, constant, back and forth motion (2 strokes per second) until the timer displays '1'.
  • Page 8: Nitrate

    FILL, DIP, READ NITRATE POWER ON PHOTOMETER Press the button to power on the Well eXact ® FILL CELL Rinse the cell 3 times with the water sample to FILL be tested and to the top to begin test. Use the included cleaning brush to clean the cell after each test to achieve the most accurate result.
  • Page 9 FILL, DIP, READ NITRATE REMOVE STRIP Remove one eXact Strip Micro NO Nitrate and set in a ® dry, convenient place. Replace cap on bottle. DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously the eXact Strip by submerging all ®...
  • Page 10: Total Alkalinity

    FILL, DIP, READ TOTAL ALKALINITY POWER ON PHOTOMETER Press the button to power on the Well eXact ® FILL CELL Rinse the cell 3 times with the water sample to FILL be tested and to the top to begin test.
  • Page 11 FILL, DIP, READ TOTAL ALKALINITY REMOVE STRIP Remove one eXact Strip Micro AL Total Alkalinity ® and set in a dry, convenient place. Replace cap on bottle. DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and...
  • Page 12: Total Hardness High

    FILL, DIP, READ TOTAL HARDNESS HIGH POWER ON PHOTOMETER Press the button to power on the Well eXact ® FILL CELL Rinse the cell 3 times with the water sample to FILL be tested and to the top to begin test.
  • Page 13: Total Hardness High

    7 prior to testing THH. AL: Total Alkalinity must be in the range of 65-220ppm. If Total Alkalinity is >220ppm, it must be conditioned with eXact Strip ®...
  • Page 14: For Best Accuracy

    FOR BEST ACCURACY The Well eXact EZ photometer has a 5 minute auto-shutoff timer. ® Each test menu can store 20 results. To retrieve the stored results, go to the desired test using the MENU key. When the desired test is displayed, press and hold down the MENU key.
  • Page 15: Troubleshooting

    The Well eXact ® EZ has been factory calibrated and will stay valid because of its exceptional quality. We are so confi dent in the Well eXact EZ, we ® offer an industry leading 2-year warranty.
  • Page 16: About

    Registration is available over the phone (+1-803-329-9712 Ext. 0) or online at sensafe.com/micro/warranty/ (Personal data is kept confi dential). The eXact photometer is warranted to ® be free from defects in materials and workmanship for a period of two (2) years from the date of purchase by the customer.
  • Page 17: Msds

    MSDS Section 1 Chemical Identifi cation / Company / Undertaking Name: EZ Open Reducer Powder Pillow For Total Iron Test Product code: 486601 used in kit 486651 Company Name: Industrial Test Systems, Inc. 1875 Langston Street, Rock Hill, SC 29730 USA Phone: (800) 861-9712, (803) 329-9712, Fax: (803) 329-9743 eMail: its@sensafe.com Section 2 Composition / Information on Ingredients...
  • Page 18 MSDS Section 7 Handling and Storage Handling requirements: Ensure there is exhaust ventilation in the area. Avoid the formation or spread of dust in the air. Avoid direct contact with the substance. Storage conditions: Store in cool, well ventilated area. Keep container tightly closed.
  • Page 19: Msds

    MSDS Section 15 Regulatory Information Hazard symbols: Harmful Risk phrases: R22: Harmful if swallowed R36/37/38: Irritating to eyes, respiratory system and skin R31: Contact with acids liberates toxic gas. R52: Harmful to aquatic organisms. Safety phrases: S22: Do not breathe dust. S36/37/39: Wear suitable protective clothing, gloves and eye / face protection.
  • Page 20: Exact ® Micro Tests & Reagents

    For a complete list of accuracies throughout all ranges, please visit sensafe.com/photometers/well-exact-ez/. For detailed instructions on using this product, contact us (see below) or visit sensafe.com/photometers/well-exact-ez For resellers and distributors - products sold in case quantities (12 units per case).

Table of Contents