eXact Eco-Check Instruction Manual

Dual wavelength advanced photometer system

Advertisement

Quick Links

Dual Wavelength Advanced Photometer System
IDEAL FOR AQUACULTURE, AQUARIUMS, LAKES,
ENVIRONMENTAL, & EDUCATIONAL TESTING
USEPA, DIN, & ISO Compliant for Free & Total Chlorine Testing
(4500-CL G, DIN Standard 38 408 G4, ISO 7393/2)
U.S. Patent No. 7,333,194, U.S. Patent No. 7,491,546, South African Patent No. 2007/0628,
EU Patent #1,725,864, and International Patent Appln. No. PCT/US2005/033985
USEPA
DIN, ISO
Compliant
For Free & Total
C h l o r i n e
(4500-Cl G, DIN STANDARD 38 408 G4, ISO 7393/2)
Manufactured By: Industrial Test Systems, Inc.
1875 Langston Street, Rock Hill, SC 29730 USA
Phone: 1-800-861-9712 - INSIDE THE U.S.
1-803-329-9712 - OUTSIDE THE U.S.
www.poolcheckonline.com
©2017 Industrial Test Systems, Inc. • EXACT
Eco-Check
Fax: 1-803-329-9743
ITS@SENSAFE.COM
WWW.SENSAFE.COM
®
is a registered trademark of Industrial Test Systems, Inc., Rock Hill, SC USA
Inde
Index:
Para
Parameter
Tot
Total Alkalinity (as CaCO
Ni
Nitrite (as NO
)
2
N
Nitrate (as NO
)
3
Ammonia (as NH
A
)
3
Total Hardness (as CaCO
Total Chlorine (DPD-4)
pH in Fresh Water
)
Phosphate (as PO
4
+2
Copper (as Cu
)
Chloride (as NaCl)
pH in Salt Water
Free Chlorine (DPD-1)
Combined Chlorine (DPD-3)
About Your Photometer
Mini Dilution Kit II Instructions
Tips for Best Accuracy
Battery Installation
Warranty (2 year)
Reorder Information
USEPA Compliance
Kit Components
Visit us online at sensafe.com/eco-check for up-to-date
product information and to register your warranty.
The eXact
Eco-Check
®
Dual-Wavelength Photometer System
is designed for use with the eXact
Strip Micro reagent delivery system.
eXact
Eco-Check is Manufactured
®
and tested in an ISO 9001 Facility.
Revision 02/24/17
486798-K Standard Kit
Page
MENU
)
4
3
5
6
7
)
8
3
9
10
11
12
13
14
15
16
3
15
17
18
18
19
19
20
®
AL1
NO2
NO3
NH4
TH5
CL6
bt7
PO8
CU9
CH0
P11
CL6
CL6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eco-Check and is the answer not in the manual?

Questions and answers

Summary of Contents for eXact Eco-Check

  • Page 1 Tips for Best Accuracy Battery Installation Warranty (2 year) Reorder Information USEPA Compliance Kit Components Visit us online at sensafe.com/eco-check for up-to-date product information and to register your warranty. Manufactured By: Industrial Test Systems, Inc. The eXact Eco-Check ® Dual-Wavelength Photometer System...
  • Page 2 Instrument: 5 (W) x 3.5 (D) x 16.5 (H) cm; (2 x 1.4 x 6.5 in) eXact® Eco-Check Photometer has been designed to offer the user a more “Green” and cost-effective alternative to testing. Instead of using a 10mL water sample, the eXact ®...
  • Page 3 ® The eXact Eco-Check meter is controlled by three buttons: ZERO/ON meter is on and this button is pressed, it zeroes the sample in the cell. Once the meter is zeroed, this zero value applies to all parameters and is stored and retained even when meter turns off.
  • Page 4 Total Alkalinity Test Procedure REMOVE STRIP ® Remove one (1) eXact Strip Micro AL, Part No. 486641 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on;...
  • Page 5: Zero Meter

    Nitrite (as NO ) Test Procedure REMOVE STRIP Remove one (1) eXact ® Strip Micro NO , Part No. 486623 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately.
  • Page 6: Remove Strip

    ) Test Procedure FRESH WATER ONLY (Salt level must be less than 400ppm) REMOVE STRIP ® Remove one (1) eXact Strip Micro NO , Part No. 486655 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately.
  • Page 7 Rinse the CELL at least 3 times with the water sample you will be testing - rinsing minimizes the potential for ® to capacity with the water sample. Add 3 drops of eXact Reagent NH , Part No. 486654-B to the CELL. For Salt Water Analysis, add 10 drops.
  • Page 8 Total Alkalinity must be in the range of 65-220ppm (as CaCO3). REMOVE STRIP ® Remove one (1) eXact Strip Micro THH, Part No. 486656 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately.
  • Page 9 DPD-4 Total Chlorine Procedure REMOVE STRIP ® Remove one (1) eXact Strip Micro CL (DPD-4), Part No. 486670 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on;...
  • Page 10 0.2mL of water sample in order to leave room for liquid reagent. ADD REAGENT AND CAP ® Shake the bottle of eXact Reagent P-pH, Part No. 486657 to mix the chemical in the bottle. Then, add two ®...
  • Page 11 Phosphate Test Procedure REMOVE STRIP ® Remove one (1) eXact Strip Micro PO , Part No. 486814 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on;...
  • Page 12 Copper Test Procedure REMOVE STRIP ® Remove one (1) eXact Strip Micro CU, Part No. 486632 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on;...
  • Page 13 Chloride Test Procedure REMOVE STRIP ® Remove one (1) eXact Strip Micro CH, Part No. 486757 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately. TURN METER ON Press the ZERO/ON button to power the meter on;...
  • Page 14 0.2mL of water sample in order to leave room for liquid reagent. ADD REAGENT AND CAP ® Shake the bottle of eXact Reagent P-pH, Part No. 486657 to mix the chemical in the bottle. Then, add two ®...
  • Page 15 (this result is automatically stored in CL6 Menu). ® DO NOT discard the sample from the Free Chlorine test if you are planning to run eXact Strip Micro DPD-3 (Combined Chlorine) Procedure. Move directly to steps 7-9 on page 16.
  • Page 16 Strip Micro CL (DPD-1 Free Chlorine) Test Procedure located on the previous page. REMOVE STRIP Remove one (1) eXact ® Strip Micro CL (DPD-3), Part No. 486638 from the bottle before beginning the test. Set the strip in a dry, convenient place and recap the bottle immediately.
  • Page 17 These should be discarded. Using these strips may give unreliable results. The eXact ® Eco-Check meter is not compatible for use with DPD-1, DPD-3, and DPD-4 powder pillows, tablets, and liquids available from other manufacturers. Accurate ® results can only be guaranteed by using genuine eXact Strip Micro strips or reagents (reorder information on page 19).
  • Page 18: Top View

    30 days from date of purchase to ® activate the warranty. The eXact photometer is warranted to be free from defects in materials and replace any part of the product which is deemed to be faulty or otherwise defective. The non-transferable returning the photometer to ITS.
  • Page 19 Eco-Check Reagent Reorder Information ® ® ® Eco-Check Systems against the AWWA, US EPA , DIN, and ISO reference test methods for chlorine. ® Eco-Check System repeatedly agrees with an EPA Compliant reference ® method greater than 99% (R...
  • Page 20: Standard Kit