Power Trim Does Not Operate (Electric Motor Operates but Sterndrive Unit Does Not Move)

Possible Cause
The trim pump oil level is low.
The drive unit is binding in the gimbal ring.

Power Trim Does Not Operate (Electric Motor Does Not Operate)

Possible Cause
Blown fuse.
Loose or dirty electrical connections or
damaged wiring.
90-8M0145546
MAY 2018
eng
Fill the trim pump with oil.
Check for obstruction. See a Mercury Diesel–authorized repair facility.
Replace the fuse.
Check all the associated electrical connections and the wires (especially the
battery cables). Clean and tighten the faulty connection. Repair or replace the
wiring.
Section 6 - Troubleshooting
Remedy
Remedy