Pinning Formula

Degree
Key System Technical Manual
Fixed Core Cylinders - All 6 Chambers
Large Format Interchangeable Cores
(Chambers 1-2-5-6)
Non-LFIC
Example
Driver Pin (DP)
10 MINUS
Plug Total
Master Wafer
(MW) Pin =
Master Wafer (MW) 2
Deepest Minus
Shallowest
Operating Cut
Plug Total (MW + BP)
Bottom Pin =
Shallowest
Operating Cut
Instructions
Bottom Pin = shallowest operating cut
Master Wafer (if required) = Deepest minus
shallowest operating cut
(Plug Total = Bottom Pin + Master Wafer)
Driver Pin = 10 MINUS Plug Total
Note: The 50-DG1 hotel mortise cylinder uses 6 pin change/master keys but with a # 5 depth cut in what would be the 7th position at the tip of the key
The 7th chamber is always loaded with a # 5 bottom pin and # 8 driver
All other chambers are loaded as if a standard fixed core cylinder
Master Key 1
2 3 4 6 4
Change Key 3
4 5 2 2 2
Driver Pin (DP) 7
6 5 6 4 6
2 2 2 4 2
Bottom Pin (BP) 1
2 3 2 2 2
6300 Large Format Interchangeable Core -
Control Chambers
(Chambers 3 and 4 Only)
LFIC
Driver Pin (DP)
Example
13 MINUS Plug
Total and
Control Driver
Control
Driver (CD) =
Control Cut PLUS 6
Control Driver (CD)
MINUS Plug Total
Master Wafer (MW) 2
Bottom Pin (BP) 1
Master Wafer
(MW) Pin =
Deepest MINUS
Shallowest
Operating Cut
Plug Total (MW +BP)
Bottom Pin =
Shallowest
Operating Cut
Instructions
Bottom Pin = shallowest operating cut
Master Wafer (if required) = Deepest minus
shallowest operating cut
(Plug Total = Bottom Pin + Master Wafer)
Control Driver (CD) = Control cut PLUS 6 MINUS
Plug Total
Driver Pin = 13 MINUS Plug Total and CD# = DP
1-800-727-5477 • www sargentlock com
Control Key 1
5 5 4 3 2
Master Key 1
5 2 6 3 2
Change Key 3
1 4 3 1 5
Driver Pin (DP) 7
5 2 3 7 5
x
x
7 4
x
4 2 3 2 3
1 2 3 1 2
5
x

Advertisement

Table of Contents
loading

This manual is also suitable for:

Degree dg1Degree dg-3