Table 29. Memory configurations—dual processor
System Capacity (in
DIMM Size (in
GB)
GB)
8
4
16
4
16
8
32
4
32
8
32
16
64
8
64
16
64
32
128
16
128
32
128
64
256
32
256
64
512
64

Removing memory modules

Prerequisites
CAUTION:
Manyrepairsmay onlybedonebyacertifiedservicetechnician. You shouldonlyperformtroubleshooting andsimple
repairsasauthorizedinyourproductdocumentation,
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
thatareshippedwithyourproduct.
1
Followthesafetyguidelineslistedinthe Safetyinstructions section.
2
FollowtheprocedurelistedintheBefore workinginside yoursystemsection.
3
Remove the coolingshroud.
WARNING:
The memory modules are hot to touch for some time after the system has been powered down. Allow the memory
modulestocoolbeforehandlingthem.Handlethememorymodulesbythecardedgesandavoidtouchingthecomponentsor
metallic contacts on the memorymodule.
CAUTION:
To ensure proper system cooling, memory module blanks must be installed in any memory socket that is not
occupied.
Removememorymoduleblanksonlyifyouintendtoinstallmemorymodulesinthosesockets.
Number of
Organization and Speed DIMM Slot Population
DIMMs
1R x8, 2400 MT/s
2
1R x8, 2400 MT/s
4
1R x8, 2400 MT/s
2
1R x8, 2400 MT/s
8
1R x8, 2400 MT/s
4
2R x8 2400 MT/s
2
1R x8, 2400 MT/s
8
2R x8 2400 MT/s
4
2R x4, 2400 MT/s
2
2R x8 2400 MT/s
8
2R x4, 2400 MT/s
4
4R x4, 2400 MT/s
2
2R x4, 2400 MT/s
8
4R x4, 2400 MT/s
4
4R x4, 2400 MT/s
8
orasdirectedbytheonlineortelephoneserviceandsupportteam.
A1, B1
A1, A2, B1, B2
A1, B1
A1, A2, A3, A4, B1, B2, B3, B4
A1, A2, B1, B2
A1, B1
A1, A2, A3, A4, B1, B2, B3, B4
A1, A2, B1, B2
A1, B1
A1, A2, A3, A4, B1, B2, B3, B4
A1, A2, B1 B2
A1, B1
A1, A2, A3, A4, B1, B2, B3, B4
A1, A2, B1 B2
A1, A2, A3, A4, B1, B2, B3, B4
Installing and removing sled components