914-Hde Diagnostic Led Header; Table 4-8: 914-Hde Diagnostic Led Header Pinout; Figure 4-9: External Led Circuit Diagram; Figure 4-10: Diagnostic Led Header - Moog FOCAL 914-HDE L1 User Manual

Modular multiplexer system, 914-x series
Table of Contents

Advertisement

4.7

914-HDE Diagnostic LED Header

The 914-HDE card includes a 10-pin header capable of driving 8 LEDs. This is useful for LED integration into an
enclosure. Each LED pin is driven low to turn on an LED, and includes a 267 ohm resistor in series to limit the
current draw. Maximum current draw per LED pin is 8 mA.
This header may optionally become an input via the diagnostic GUI with firmware revisions greater than B1.
The LED header J9 is FCI P/N 20021521-00010T1LF, and the mating part is FCI P/N 20021444-00010T1LF. This
can be used with most 0.050" (1.27mm) spacing ribbon cables.
Pin
Name
1
3.3V
2
LINK
3
LINK FAULT
4
VIDEO
5
ETHERNET
6
SER1 RX
7
SER1 TX
8
SER2 RX
9
SER2 TX
10
GND
Focal Technologies Corporation
A Moog Inc. Company
Model 914-X Series Modular Multiplexer System User Manual

Figure 4-9: External LED Circuit Diagram

Table 4-8: 914-HDE Diagnostic LED Header Pinout

3.3V
This pin can be used to drive the LEDs, Maximum current is 0.5A.
Indicates a valid optical link is being received. Active low.
Indicates that insufficient optical power is present. Active low.
Indicates a valid video signal is present when lit. Active low.
Indicates that an Ethernet link is established locally. Active low.
Flashing LED indicates serial channel 1 receive activity. Active low.
Flashing LED indicates serial channel 1 transmit activity. Active low.
Flashing LED indicates serial channel 2 receive activity. Active low.
Flashing LED indicates serial channel 2 transmit activity. Active low.
Ground

Figure 4-10: Diagnostic LED Header

Description
Document Number: 914-0601-00 Rev. 5.0
Page 4-7