914-Hdv2 Power; Table 7-1: Power Connector Pinout; Figure 7-6: Power Input Connector Location - Moog FOCAL 914-HDE L1 User Manual

Modular multiplexer system, 914-x series
Table of Contents

Advertisement

7.1.3 914-HDV2 Power

Power to the 914-HDV2 card is provided through connector J2, Molex P/N 09-75-2024. The mating plug is Molex
P/N 26-03-4020 with crimps P/N 08-52-0113. The pinout is provided in the table and figure below.
Table 7-1: Power
Connector Pinout
Pin #
Function
1
GND
2
VCC
The recommended input voltage range is 4.5 VDC to 13.0 VDC (typically +5 VDC regulated). Nominal power
consumption is 2.8 W, increasing to 3.2 W at 60
The onboard surface mount fuse, F1, is rated to 2A and is not intended to be field replaceable. If the power fuse
is blown, the card should be evaluated for damage by the factory or trained service personnel prior to any repair.
Focal Technologies Corporation
A Moog Inc. Company
Model 914-X Series Modular Multiplexer System User Manual

Figure 7-6: Power Input Connector Location

C ambient temperature. Power leads should be AWG 18 – 20.
o
Document Number: 914-0601-00 Rev. 5.0
Page 7-4