4.2

914-HDE Power

Power to the 914-HDE card is provided through connector J3, Molex P/N 09-75-2024. The mating plug is Molex
P/N 26-03-4020 with crimps P/N 08-52-0113. The pinout is provided in the table and figure below.
Table 4-2: Power
Connector Pinout
Pin #
Function
1
2
The recommended input voltage range is 4.5 VDC to 13.0 VDC (typically +5 VDC regulated). Nominal power
consumption is 5 W, increasing to 5.5 W at 60
expansion card power requirements. Power leads should be AWG 18 – 20. Refer to section 10.5 for more details
on the system electrical and environmental specifications.
The onboard surface mount fuse, F1, is rated to 2A and is not intended to be field replaceable. If the power fuse
is blown, the card should be evaluated for damage by the factory or trained service personnel prior to any repair.