6.3.7 914-AX Configuration and Diagnostics

The 914-AX does not require any specific configuration, however, the installed AIB module may require
configuration. Please refer to the AIB Plug-In Modules User's Guide 700-0271-00 for configuration details specific
to the installed AIB module.
Up to four 914-AX with associated AIB modules may be added to a 914-HDE system. The 914-AX closest to the
914-HDE will show up as channel one in the diagnostic GUI. Tx and Rx activity status may be observed via the
914-HDE diagnostics in the "Low Speed Expansion" tab.

Figure 6-31: 914-AX Data Activity

Focal Technologies Corporation
Page 6-24
Document Number: 914-0601-00 Rev. 5.0
A Moog Inc. Company