Troubleshooting

Troubleshooting
The sensor is not a serviceable part. Replace it if
it is malfunctioning.
Problem
No flow volume displayed at monitor-
ing unit
Fluid is not flowing
8
Cause
Flow volume is too low to measure
Fluid is not flowing
Damaged cable
Improper input voltage to sensor
Damaged sensor
Clogs in fluid line or in meter
Gears worn or damaged
Solution
Increase flow volume.
See Problem: Fluid is not flowing,
below.
Replace cable.
Make sure input power is 10-30 Vdc.
Replace sensor if it is malfunctioning.
Clean fluid line and/or meter; see
Maintenance section.
Service meter; see Maintenance
section.