Troubleshooting

Relieve pressure, page 6, before you check or repair the meter. Be sure all other valves, controls and pump are
operating properly.
When calling for Technical Assistance you may be asked to provide the Software Version that is being used by
your meter. Refer to F
meter.
Problem
Battery icon is blinking.
Display does not activate.
Cannot read display
Slow or no fluid flow.
Displayed dispensed amount is not
accurate.
312865A
. 10, page 10, item #1 for help determining where this information is shown on your
IG
Batteries are low.
Batteries are defective.
Electronic control is malfunctioning.
Contrast is set too high or too low to
be viewed in work area
Filter is clogged.
Pump pressure is low.
Twist lock nozzle not fully open.
Shut-off valve is not fully open.
Foreign material is jammed in the
meter housing.
Unit needs to be calibrated for the
fluid that is being dispensed.
Cause
Replace batteries, page 26.
Replace batteries, page 26.
Replace the electronic bezel assem-
bly. Order ME14 and PE14 Meter
Electronic Repair Kit. (See ME Meter
Parts page 26 or PE Meter Parts
page 30 to identify which kit is
required for your meter).
Adjust contrast. See Adjusting
Screen Contrast Using LEFT or
RIGHT ARROWS, page 9.
1. Relieve pressure, page 6.
2. Clean or replace filter. Order Fil-
3. If the problem remains, contact
Increase pump pressure.
Aim nozzle into bucket or rag. Fully
open nozzle.
Do not trigger meter when nozzle
is closed! If you do accidentally trig-
ger the meter with the nozzle closed,
point nozzle into a waste bucket and
open the nozzle to relieve pressure
and expel built up fluid.
Fully open shut-off valve.
Contact your Graco distributor for
repair or replacement.
Calibrate the meter for the fluid that is
being dispensed. See Calibrate
Screen, page 13.
Troubleshooting
Solution
ter Kit 255885.
your Graco distributor for repair
or replacement.