Technical Data

Technical Data
Category
Maximum Working Fluid Pressure 6000 psi (41 MPa, 410 bar)
Flow Range**
Maximum Operating
Temperature
Maximum Ambient
Temperature
Fluid Viscosity Range
Maximum Cable Length
Flow Meter Inlet/Outlet
Resolution (K-Factor)
Accuracy
Repeatability
Supply Voltage
Typical Current
Approvals
Wetted Parts
* For most commonly used coatings, the flow meter reading will be accurate to within +/- 0.25%. Accuracy will diminish
at low viscosities and low flow rates.
** The Flow Range is a generic rating meant to cover a
wide variety of materials and applications. However,
the Flow Range may be different depending on the
Graco system in which the Flow Meter is used. To
find the Flow Range for a specific Graco system,
refer to that system's Operation Manual.
18
Data
Models 246190, 246340, 280560, 15V820, and 24R174: 0.05 to 6.0 gpm (190
to 22,712 cc/min)
Models 246652 and 24P688: 0.05 to 2.0 gpm (190 to 7571 cc/min.)
Models 246190, 246652, and 24P688: 180° F (82° C)
Models 280560 and 15V820: 140° F (60° C)
Models 246340 and 24R174: 400° F (204° C)
Models 246190, 246652, 246340, 24P688, and 24R174: 180° F (80° C)
Models 280560 and 15V820: 140° F (60° C)
30 - 1,000,000 cps
200 ft (61 m)
3/4 npt(f)
Models 246190, 246340, 280560, 15V820, and 24R174 - (0.286 cc/pulse)
(3500 pulses/liter)
Models 246652 and 24P688 - (0.143 cc/pulse) (7000 pulses/liter)
+/- 0.25%*
+/- 0.1%
10 - 30 Vdc
15 mA
CE: Models 246190, 246652, 246340, 280560, 24P688, and 24R174
EX: Model 15V820 only.
303 Stainless Steel, 440 SST, Carpenter Technology 7-mo Plus
Tungsten Carbide, PTFE
®
Duplex SST,
309834W