API Command List Instructions (cont.)
IDX
Function Description
1
To execute a sink power
by CEC
2
To define a sink power
by CEC automatically
3
To get a sink power by
CEC automatically
4
To define a Delay Time
to execute a sink power
off when on active signal
5
To get a Delay Time to
execute a sink power off
when on active signal
Instruction Manual - 4K/60 Scaler
Syntax
Command:
CSP#T
Return:
CSP#T
Description:
CECPWR_ONOFF will control sink power on
or off
SP#: #={0, 1}
0 : OFF
1 : ON
Command:
CSPA#T
Return:
CSPA#T
Description:
SPA#: #={0, 1}
0 : Disable
1 : Enable
Command:
SSPAT
Return:
SSPAT( # )
Description:
#: #={0, 1}
0 : Disable
1 : Enable
Command:
CD#SPT
Return:
CD#SPT
Description:
CECAUTO_DELAY is short for CEC auto
Power Delay Timing
D#: #={1~30MIN}
Command:
SDSPT
Return:
SDSPT( # )
Description:
CECAUTO_DELAY is short for CEC auto
Power Delay Timing
#: #={1~30MIN}
API Command List Instructions
Example
Command:
CSP1T[CR/LF]
Return:
CSP1T[CR/LF]
Description:
Executes the sink power on.
Command:
CSPA1T
Return:
CSPA1T
Description:
Enable control the sink power by CEC
automatically.
Command:
SSPAT
Return:
SSPAT( 1 )
Description:
Enable control the sink power by CEC
automatically.
Command:
CD5SPT
Return:
CD5SPT
Description:
Define Delay 5 minutes to control the sink
power off when on active signal.
Command:
SDSPT
Return:
SDSPT( 5 )
Description:
Get Delay time to control the sink power off
when on active signal is 5 minutes.