API Command List Instructions

General rules for using BCS commands
Command strings typically are not case-sensitive.
All command strings must end with the Take command "T" which tells the system ot execute the command.
"O" is the letter O, no the number zero (0).
Entering "X" at any point in a command string cancels the command.
A command cannot be canceled after the "T" has been entered.
Command strings cannot be edited. If a mistake has been made, enter an "X" and then reenter the command.
To specify multiple outputs, inputs, levels, or local presets, enter a space " " between each number. Multiple inputs are only
valid in Disconnect commands.
To specify a range of outputs, inputs or local presets, enter a space " " between each number. Multiple inputs are only valid in
Disconnect commands.
To specify a range of outputs, inputs or local presets, insert a colon ":" between the lowest and highest numbers of the range
(not supported if the command is otherwise invalid, e.g., cannot specify a range of inputs in a Change command; the first
input only would be routed.).
Colons ":" and spaces " " can be used in the same command string.
If the level designation "L" is ommited, the command is executed on the default level, which is normally Level 0.
RS232 Default Setting
Parameters
Baud Rate
Data bits
Parity
Stop bits
Flow control
Instruction Manual - 4K/60 Scaler
Value
9600 bps
8 bits
None
1 bit
None
API Command List Instructions
15