Technical Data - Gardena PowerCut Li-40/30 Operator's Manual

Battery trimmer
Hide thumbs Also See for PowerCut Li-40/30:
Table of Contents

Advertisement

Problem
¥
Error-LED
on the battery
flashes
ß
Wb
¥
Error-LED
on the battery
illuminates
Charging control lamp
the charger does not illuminate
ß
ß
Lc
Wc
Charging control lamp
the charger flashes rapidly
(4 times per second)
ß
Error-LED
on the charger
Wc
flashes
ß
Error-LED
on the charger
Wc
illuminates
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers
approved by GARDENA.

7. TECHNICAL DATA

Battery Trimmer
Cutting filament thickness
Cutting width
Rpm of filament cassette
(normal/Eco)
Cutting filament supply
Cutting filament feed
Weight (without Battery)
Sound pressure level L
Uncertainty k
pA
Sound power level L
WA
measured/guaranteed
Uncertainty k
WA
24
Possible Cause
Under voltage.
Battery temperature is out of
range.
Battery error / battery defective.
å
on
Battery charger or charging
cable are not connected
correctly.
å
on
Battery temperature is out of
range.
Battery error.
Temperature inside the charger
is too high.
Unit
Value (Art. 9827)
mm
1.6
cm
30
rpm
8500 / 7500
m
6
Tip mechanism
kg
3.2
1)
83
pA
dB (A)
3
2)
:
93 / 94
dB (A)
1
Remedy
v Charge the battery.
v Use the battery in surroundings
where temperatures are
between – 10 °C and 40 °C.
v Contact the GARDENA Service.
v Connect the battery charger
and charging cable correctly.
v Use the battery in surroundings
where temperatures are
between – 10 °C and 40 °C.
v Remove the battery and
check that you use an original
GARDENA battery.
v Contact the GARDENA service.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents