PARAMETER
Main Current Limit
50 A – rated current
Plug Current Limit
Curtis 1204M/1205M/1209M/1221M Manual
CURRENT MENU
ALLOWABLE
RANGE
The main current limit can be programmed, in 5A increments, up to the
controller's 2-minute current rating (see model chart in Appendix C).
50  –   2 50 A
Plug braking occurs when the opposite direction is selected with the
forward/reverse switch without releasing the throttle. The vehicle brakes
smoothly to a stop and then accelerates in the other direction.
The plug braking current limit is set by this parameter.
Plug braking can be either fixed or throttle-variable; see Variable
Plug parameter (page 23). During fixed plug braking, the plug braking
current is the programmed Plug Current Limit value. During variable
plug braking, the plug braking current varies with the amount of applied
throttle, from 50% to 100% of the programmed Plug Current Limit value.
3 — PROGRAMMABLE PARAMETERS:
DESCRIPTION

Current Parameters

19