Sensitivity: Determine the sensitivity for the motion sensing by entering a value between
0 and 9. The higher the value, the higher the motion sensing sensitivity.
Compensation of light changes: This option can be selected to prevent the movement
sensing from being influenced by changing light conditions.
Recognition at digital input: If an alarm message is triggered via the alarm connection,
this can be accepted by the WiFi Network Camera if this option has been activated.
Alarm level: Determines whether an alarm is triggered if no voltage is applied to the alarm
input (setting low) or if voltage is applied (setting high).
Report at digital output: Any alarm message at the WiFi Network Camera is forwarded via
the digital output if this option has been activated.
Alarm level: Determine whether the alarm is triggered at the digital output by an applied
voltage (setting high) or by a cessation of the voltage (setting low).
Report to email: Activate this option if an email message should be triggered in case of an
alarm incident.
Report to FTP: Activate this option if images should be saved to the FTP server in case of
an alarm.
Interval: Determine at what interval images should be saved to the FTP server in case of
an alarm. The value is in seconds.
Report to HTTP: Activate this option if an HTTP address should be contacted in case of an
alarm incident.
URL: Determine which HTTP address should be contacted in case of an alarm incident.
Click on "Save" to accept changes to the settings. Changes to the alarm settings are accepted
without the WiFi Network Camera having to be restarted.