Code
Panel display
(last 4 digits)
(Large LCD)
1030
GARO W1221
1031
GARO W1222
1032
GARO W1223
1034
GARO W1225
1035
GARO W1231
1036
GARO W1232
1037
GARO W1233
1038
GARO W1234
1039
GARO W1235
103A
GARO W1226
1040
GL2: W0501
The memory is full.
1041
GL2: W0502
The parameter is out
of range.
1043
GL2: W0504
This command is not
supported.
1047
GL2: W0903
The memory is full.
Panel display
Explanation/Detection sequence
(Small LCD)
GARO W1221
(Image mode)Unknown command
A character that is located within bounds of
a group character or end parameter
character but that is not defined as a
command has been detected during Image
mode command decoding.
GARO W1222
(Image mode) Invalid parameter count (no
parameters)
A numeric field has not been identified as
being numeric during Image mode
command decoding.
GARO W1223
(Image mode) Required item missing
A character out of bounds has been
detected where a group or end parameter
character ought to exist, during Image
mode command decoding.
GARO W1225
(Image mode)Other warning
A character other than <ESC> has been
detected right after the image mode
analysis module entered Image mode or
when the decoding of a single command
ended.
GARO W1231
(Setup mode)Unknown command
A command character string other than
RESET, SET, OPCMT0 and OPCMT2 has
been detected in a PJL command.
GARO W1232
(Setup mode)Invalid parameter count
Too many or too few parameters have been
detected during Setup mode command
decoding.
GARO W1233
(Setup mode) Required item missing
The exit parameter is missing in the
EnterGAROMode command and the
UniversalExitLanguage command used in
Setup mode.
GARO W1234
(Setup mode)Data out of bounds
A character string that is not defined as an
environmental variable has been detected.
An unknown environmental variable has
been detected.
A character string that is not defined as an
environmental variable value has been
detected.
The value of an unknown environmental
variable has been detected.
GARO W1235
(Setup mode) Other warning
A character string other than the @PJL
prefix has been detected while the analysis
module was idle.
GARO W1226
(Image mode) Image processing table error
No image processing table is being
transmitted, a required image processing
table is unavailable, or an image processing
table contains a value out of bounds.
GL2: W0501
HP/GL2 error; Insufficient memory
capacity
The size of drawing data exceeds the
processing capacity.
GL2: W0502
HP/GL2 error; invalid parameter
Data having an invalid number of types of
parameters that follow the command has
been detected.
GL2: W0504
HP/GL2 error; Invalid command
A command that is not defined in HP-GL/2
or HP RTL is included.
GL2: W0904
HP/GL2 error; replot buffer overflow
Data storage buffers have run short.
Chapter 6
Remedial Action
1. Identify the model.
2. If the error has occurred with RIP,
try with the printer driver.
3. Try in an alternative environment (I/
F, PC).
1. Retransmit.
2. Check with a different interface
choice.
3. Try by printing other data.
4. With RIP, print from the print
driver.
Supplement: If this error occurs, the
print result would appear blank.
1. Reduce the size of rendering data.
2. Replace with HP RTL data for
manipulation with On The Fly*.
*: On The Fly: The method to transmit
data in sequence from paper. The
software that generates HP-GL/2 data
has this option to specify. Select this
option to save the memory usage of the
printer.
Verify the data and fix it.
Verify the data and fix it.
1. Reduce the size of rendering data.
2. Replace with HP RTL data for
manipulation with On The Fly*.
*: On The Fly: The method to transmit
data in sequence from paper. The
software that generates HP-GL/2 data
has this option to specify. Select this
option to save the memory usage of the
printer.
6-5