Wiring Diagram - Standard Pulser - Macnaught MX06S Instruction Manual

Oval gear flowmeter, mx06/mx100/mx09/mx12/mx19/mx25/mx40/mx50/mx75 series
Table of Contents

Advertisement

WIRING DIAGRAM 1
Output Signals
Reed Switch
(Mechanical Sensor)
Hall Effect IC
(Electronic Sensor)
1. Contact rating maximum is 10W. Neither current nor voltage maximums should be exceeded in achieving this.
PCB
Output type A,D,E,F,G,H
Pulser Specifications
Standard Pulse Meter
Current
Voltage
Contact Rating
Maximum Supply Current
Maximum Output Current
Operating Voltage
Transistor Type
Maximum
Maximum
1
Maximum
2x Digital (Square Wave)
500mA
30V DC
10W
7.5mA
25mA
4.5V to 24V DC
Open-Collector NPN