Industrial register mechanical upgrade

Advertisement

Quick Links

Industrial Register MH450
Mechanical Register Upgrade
Important Information
PLEASE READ THIS INFORMATION
CAREFULLY BEFORE USE!
Ensure that the fluid supply to the
meter is isolated and disconnected,
and the line pressure is released
before disassembly.
To prevent damage to the meter
slowly fill the system with fluid
(this will prevent damage caused by
air purge).
1
Note:
Failure
to
do
damage
the
meter.
applications, turn off the pump at
the end of each day.
MS746
1004
0002
this
could
For
pump

Advertisement

loading
Need help?

Need help?

Do you have a question about the MH450 and is the answer not in the manual?

Questions and answers

Summary of Contents for Macnaught MH450

  • Page 1 MS746 1004 0002 Industrial Register MH450 Mechanical Register Upgrade Important Information and the line pressure is released Note: Failure this could before disassembly. damage meter. pump PLEASE READ THIS INFORMATION To prevent damage to the meter applications, turn off the pump at...
  • Page 2 (Item 5) and remove the 1] Remove the 4 clamp ring screws facia plate (Item 6) (Item 1) 2] Remove the Clamp ring (Item 2) Installing the MH450 Register shown in Figure 6. Note: The (Item 2) tighten the 4 screws register body...
  • Page 3 Register Parts Listing Figure 7 Register Assembly Complete assembly order MH450s Item No. No Off. Part No. Spare Part Part Description PC210 Clamp Ring Screw MS733 MS733s Clamp Ring MS745 MS745s Glass Face MS764 Channel Seal MS439 Screw MS734s includes Item 5 MS768 Facia - Litres M4 MS769...
  • Page 4 Macnaught Pty Ltd ABN 66 000 075 785 41 - 49 Henderson Street, Turrella, Sydney, NSW, Australia 2205 PO Box 90 Arncliffe, Sydney, NSW, Australia 2205 International Telephone +61 2 9597 0401 Facsimile +61 2 9597 7773 Email: sales@macnaught.com.au - Web www.macnaught.com.au...