P2 Parameter List - Panasonic AMK3000P22 Installation Manual

Mk300 series. 1-phase 200v(0.2kw-2.2kw), 3-phase 400v(0.75kw-15kw)
Table of Contents

Advertisement

P2 Parameter List

No.
Function name
P201 Load Rating
P202 Automatic Tuning
P203 Motor Capacity
Pole Number of
P204
Motor
Motor Rated
P205
Voltage
Motor Rated
P206
Frequency
Motor Rated
P207
Current
P208 Primary Resistor
P209 Secondary Resistor
P210 Exciting Inductance
Leakage
P211
Inductance
P212 Exciting Current
Speed Control
P213
Proportion Amplitude
Speed Control
P214
Integral Amplitude
P215 Torque Limit Level
P216 2nd Motor Capacity
Pole Number of 2nd
P217
Motor
Rated Voltage of 2nd
P218
Motor
Rated Frequency of
P219
2nd Motor
Rated Current of 2nd
P220
Motor
Primary Resistor of
P221
2nd Motor
Secondary Resistor
P222
of
2nd Motor
Changes
during RUN
0: Heavy load rating
1: Light load rating
0: No tuning
1: All tuning
0.2 : 0.2kW
0.4 : 0.4kW
0.7 : 0.75kW
1.5 : 1.5kW
2.2 : 2.2kW
2 : 2-pole 4 : 4-pole 6 : 6-pole
0 to 500
10.0 to 120.0
0.01 to 99.99
0.00 to 99.99 (*8)
0.00 to 99.99 (*8)
0.0 to 999.9 ,1000 to 5000 (in increments of
1 mH)
0.0 to 999.9
0.01 to 99.99
0.01 to 10.00
0.01 to 10.00
50 to 400
0.2 : 0.2kW
0.4 : 0.4kW
0.7 : 0.75kW
1.5 : 1.5kW
2.2 : 2.2kW
2 : 2 Pole 4 : 4 Pole 6 : 6 Pole
0 to 500
10.0 to 120.0
0.01 to 99.99
0.00 to 99.99 (*8)
0.00 to 99.99 (*8)
Setting range
3.7 : 3.7kW
5.5 : 5.5kW
7.5 : 7.5kW
11. : 11kW
15. : 15kW
3.7 : 3.7kW
5.5 : 5.5kW
7.5 : 7.5kW
11. : 11kW
15. : 15kW
Initial
Unit
value
0
0
*4
Pole
4
1[V]
*5
0.1[Hz]
50.0
0.01[A]
*4
0.01[Ω]
*4
0.01[Ω]
*4
0.1[mH]
*4
0.1[mH]
*4
0.01[A]
*4
0.01
*4
0.01
*4
1[%]
*4
*4
Pole
4
1[V]
*5
0.1[Hz]
50.0
0.01[A]
*4
0.01[Ω]
*4
0.01[Ω]
*4
52