No.
Function name
12th Step Speed
P312
Frequency
13th Step Speed
P313
Frequency
14th Step Speed
P314
Frequency
15th Step Speed
P315
Frequency
16th Step Speed
P316
Frequency
2nd Acceleration
P317
Time
2nd Deceleration
P318
Time
3rd Acceleration
P319
Time
3rd Deceleration
P320
Time
4th Acceleration
P321
Time
4th Deceleration
P322
Time
Rotation Direction
P323
of
Timer Operation
Continuous
P324
Operation Times of
Timer
Continuous
P325
Operation Mode of
Timer
Continuous Standby
P326
Time of Timer
Operation
1st Step Speed
P327
Runtime
2nd Step Speed
P328
Runtime
3nd Step Speed
P329
Runtime
4nd Step Speed
P330
Runtime
5nd Step Speed
P331
Runtime
6nd Step Speed
P332
Runtime
Changes
during RUN
0.0, 0.2 to 400.0
○
0.0, 0.2 to 400.0
○
0.0, 0.2 to 400.0
○
0.0, 0.2 to 400.0
○
0.0, 0.2 to 400.0
○
0.04 to 3600
○
0.04 to 3600
○
0.04 to 3600
○
0.04 to 3600
○
0.04 to 3600
○
0.04 to 3600
○
0 to 255
-
0 · 1 to 9999
○
0: Return to zero dead stop status and
then start next cycle.
○
1: Change to 1st multi-step speed
frequency for the next cycle.
0.0 · 0.1 to 6553
○
0.0 · 0.1 to 6553
○
0.0 · 0.1 to 6553
○
0.0 · 0.1 to 6553
○
0.0 · 0.1 to 6553
○
0.0 · 0.1 to 6553
○
0.0 · 0.1 to 6553
○
Setting range
Initial
Unit
value
0.1[Hz]
32.5
0.1[Hz]
35.0
0.1[Hz]
40.0
0.1[Hz]
45.0
0.1[Hz]
50.0
0.01[sec]*9
*4
0.01[sec]*9
*4
0.01[sec]*9
*4
0.01[sec]*9
*4
0.01[sec]*9
*4
0.01[sec]*9
*4
0
-
1[times]
1
0
-
0.1[sec]
0.0
0.1[sec]
0.0
0.1[sec]
0.0
0.1[sec]
0.0
0.1[sec]
0.0
0.1[sec]
0.0
0.1[sec]
0.0
54