Table Of Contents - Panasonic AMK3000P22 Installation Manual

Mk300 series. 1-phase 200v(0.2kw-2.2kw), 3-phase 400v(0.75kw-15kw)
Table of Contents

Advertisement

No.
name
JOG
P020
Acceleration
JOG
P021
Deceleration
JOG
P022
Operation
by Panel
Electronic
P023
Thermal
Selection
Thermal
P024
Current
Setting
Overcurrent
Stall
P025
Prevention
Function
Overvoltage
Stall
P026
Prevention
Function
Current
P027
Limit
Function
P028 OCS Level
Retry
P029
Function
Selection
Retry
P030
Count
P031 Start Mode
Ride-
through
P032
Restart
Selection
Standby
P033
Time
41
Changes
during RUN
0.04 to 3600
0.04 to 3600
0: JOG operation by panel disabled
1: JOG operation by panel enabled (JOG operation
by external control disabled)
2: JOG operation by panel enabled (JOG operation
by external control enabled)
0: OL trip occurs with current up to 140% of its
rating for 1 minute.
1: Without output frequency derated
2: With output frequency derated
3: Forced air-cooled motor specification
0.1 to 100.0
0: Overcurrent stall prevention function OFF
Overcurrent trip prevention function OFF
1: Overcurrent stall prevention function ON
Overcurrent trip prevention function ON
2: Overcurrent stall prevention function OFF
Overcurrent trip prevention function ON
3: Overcurrent stall prevention function ON
Overcurrent trip prevention function OFF
0: Stall prevention function OFF
1: Stall prevention function ON (Regenerative
braking resistor ON/OFF function disabled)
0.0 · 0.1 to 9.9
1 to 200
0: No retry function
1: Only for abnormal overcurrent
2: Only for abnormal overvoltage
3: Only for abnormal overcurrent/overvoltage
1 to 10
0: Run
1: OP stop
2: Run after standby time elapse
3: OP stop (standby time)
0: Restart mode 1
1: Restart mode 2
2: Restart mode 3
3: Restart mode 4
0.1 to 100.0
Initial
Unit
value
0.01
*4
0.01
*4
0
2
0.1[A]
*4
1
1
0.1[sec]
0.0
1[%]
140
0
1
1
0
0.1[sec]
0.1

Hide quick links:

Advertisement

Table of Contents
loading