Page 3
BEETLE/ iScale TOP _____________________________________________________________________ Introduction The new BEETLE/ iScale TOP is an extension of the BEETLE /M POS System. This new construction allows the use of an additional Scale Controller so that a scale can be connected to this controller. The controller processes all scale informations, from tare default to zero position.
BEETLE/iScale TOP _____________________________________________________________________ BEETLE /iScaleTOP Front View _____________________________________________________________________...
BEETLE/iScale TOP _____________________________________________________________________ Setting up the device Set up the BEETLE /iScaleTOP system so that it is not subject to any extreme environmental conditions. Protect the device from shocks, dust, moisture, heat and strong magnetic fields. Always be sure that the side ventilation slots of the BEETLE /iScaleTOP are not blocked, thus ensuring that the device always has sufficient ventilation.
Page 9
BEETLE/ iScale TOP _____________________________________________________________________ Vertical Installation The following minimum clearances must also be provided in vertical mounting into a confined furniture in free convection to ensure sufficient ventilation: upwards: 50 mm downwards: 50 mm A vertically installed device therefore has to be placed on a rig (spacer made of non-combustible material) that guarantees sufficient ventilation and a minimum clearance of 80 mm to the bottom of the furniture.
BEETLE/iScale TOP _____________________________________________________________________ Also make sure that the calibration seal/calibration switch at the rearside of the device is visible and accessible without greater effort! If access is only possible from one side, turn the device so (e.g. verti- cally 180 degrees), that the rearside of the BEETLE is accessible. Technical Specifications Foot Print Width...
Page 11
BEETLE/ iScale TOP _____________________________________________________________________ Storage requirements EN 60721-3-1, class 1k2 Environmental test IEC 68 / EN60068 5° C –40° C Air temperature: 5% r.h. (1g/m 3 ) –85% r.h. (25 g/m 3 ) 0.5 K/min Humidity: Temperature fluctuation:0.5 K/min (max. 7.5K/30min) Transport requirements EN 60721-3-2, class 2k2 Environmental test IEC 68 / EN60068...
BEETLE/iScale TOP _____________________________________________________________________ Interfaces: Power input +5V, +12V 4pin hard disk connection COM1 RS232 9pin DSUB connector COM2 current loop 15pin DSUB connector Test connector 2x7 pin Internal LCD interface to VGA/4 MUX Controller 26pin Zif connector Calibration switch with plastic protecting ring and calibration seal Power Consumption: P5v (VCC): 300mA...
Page 13
Wincor Nixdorf International GmbH, 06/2005 D-33094 Paderborn Bestell-Nr. / Order No.: 01750093135A...
Need help?
Do you have a question about the BEETLE /iScale TOP and is the answer not in the manual?
Questions and answers