Rounding Off Jobs; Setting The Flush Volume - Viega 8461.18 Instructions For Use Manual

Module with empty pipe for shower
Table of Contents

Advertisement

X3
X2
X1
3.2.4

Rounding off jobs

3.2.5

Setting the flush volume

Small flush volume
Viega Steptec WC module with empty pipe for shower WC (AquaClean)
Lead empty pipe from the switch or button into the concealed cis-
tern, to connect the concealed socket and concealed cistern.
Positioning of the cistern power pack
X1= max. 0.75 m
n
n
X2= max. 2.75 m with an extension cable, 1 x article number 628 505
X3= max. 4.75 m with two extension cables, 2 x article number 628
n
505
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide
Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge.
Grout the abutting edges and joints with a suitable filler.
Observe the instruction manual for the cladding panels for more
information.
Reserve a recess for the shower WC (AquaClean). In addition,
observe the manufacturer's instructions.
Immediate re-flushing of the flush volume is possible at the
factory settings.
The WC module is factory-set at a small flush volume of approx. 3 l. The
small flush volume can be set at three levels: approx. 3 l / 3.5 l / 4 l.
Remove the drain valve from the concealed cistern.
Handling
19 from 21

Advertisement

Table of Contents
loading