YASKAWA CDBR-****D User & Installation Manual page 58

Ac drive option braking unit, braking resistor unit
Table of Contents

Advertisement

7 Setting and Confirming CDBR Braking Unit Operation
Braking Activation Voltage Rotary Switch (S3)
Set the braking activation voltage rotary switch S3 to match the power supply of the main
circuit. Refer to
Table 13
voltage.
Note: Rotary switch S3 does not typically require adjustment.
NOTICE: Consider the amount of voltage fluctuation in the DC bus when changing rotary switch S3 setting
values. Setting the braking activation voltage to a low value and energizing the drive may activate the CDBR
and overheat the braking resistor.
NOTICE: Firmly click the switch into the proper position. A switch stuck between positions may cause the
CDBR to operate incorrectly.
Figure 26
Table 13 Rotary Switch S3 Settings and Braking Activation Voltage
200 V Class
Input
Setting
Voltage
(V)
0
160
1
170
2
175
3
185
4
190
5
200
6
208
7
215
8
220
9
230
<1>
<1> Default Setting
58
YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual
for details on rotary switch S3 position and braking activation
Figure 26 Braking Activation Voltage Rotary Switch (S3)
Braking
Activation
Voltage (V)
(PN Bus
Voltage)
270 (TYP)
282 (TYP)
294 (TYP)
307 (TYP)
319 (TYP)
331 (TYP)
343 (TYP)
356 (TYP)
368 (TYP)
380 (TYP)
400 V Class
Braking
Input
Activation
Voltage
Voltage (V)
(V)
(PN Bus
Voltage)
380
630 (TYP)
390
644 (TYP)
400
659 (TYP)
405
673 (TYP)
415
688 (TYP)
425
702 (TYP)
430
717 (TYP)
440
731 (TYP)
450
746 (TYP)
460
760 (TYP)
Default: 9
600 V Class
Braking
Input
Activation
Voltage
Voltage (V)
(V)
(PN Bus
Voltage)
500
825 (TYP)
505
839 (TYP)
515
853 (TYP)
525
867 (TYP)
530
881 (TYP)
540
894 (TYP)
550
908 (TYP)
555
922 (TYP)
565
936 (TYP)
575
950 (TYP)

Hide quick links: