Installation Instructions
Creating Exhaust Vent Openings in the Mounting Backplate
Refer to Illustration 1.3 for these steps.
1.
Cut out the exhaust openings in the mounting backplate. The openings must match the drive module vent openings.
2.
Drill the 12 screw holes around the exhaust (top) vent openings and insert the 12 M5 X 12 pem studs.
3.
Drill the 8 mounting holes and insert the 8 M10 pem nuts.
Illustration 1.3 Exhaust Vent Dimensions for Mounting Plate
MI92L102
In-bottom/Out-back Cooling Kit for VLT®
Parallel Drive Modules
VLT® Series FC 102, FC 202, and FC 302
Danfoss A/S © 04/2016 All rights reserved.