iR ADV C5500 series Advance Maintenance Guide
Procedure
M7
Clean the Fixing
Delivery Guide,
Delivery Roller and
Inlet Guide.
Detail
1.
Open the Fixing cover, inspect and clean the
Fixing Inlet Guide. Delivery Roller, Delivery Guide
Check
Note
Point;
Removal of Fixing Inlet Guide is not needed. The
Fixing Inlet Guide could be cleaned when inside
of machine. If very contaminated and
Scratched replace the Fixing Inlet Guide,
FC0-4934-000.
Also rotate/check the orange Delivery Roller
(FE4-3689-000) and Bushings (FS5-1943-000 Qty
2 for noise/wear. Lube the bushings with high
temp grease to stop noise. Bushings will become
oval instead of round over time.
Clean
If you install the Fixing Separation Guide (FC8-
5043-030) (Not part of the Fixing film unit. You
must remove from old to put on new). Be sure
to check that it is installed properly. if Upside
down, 0107 JAM will occur.
Action at Replacement:
abnormal noise, be sure to apply a small amount
of grease to the bearing fitting part of the Fixing
Pressure Roller Shaft. Grease that can be used [
CK-8102 (HP300); QY-0035 (HP300) and FY9-6036
(SE1107) ] See Service Manual
Time
Visual Check
min
Clean
In order to prevent
1
5
min