Checking the accuracy of the vertical plumbing
FR
Set up the instrument on an even and flat surface.
Allow the instrument to level.
IT
ES
Checking the upper plumbing point:
PT
NL
DA
SV
NO
FI
JA
ZH
KO
Checking the lower plumbing point:
PL
HR
HU
RU
CZ
EL
LT
LV
Set up the laser on its tripod or wall mount bracket
EE
near point A1 at a minimum distance of 1.5 m from
point B1. The horizontal laser is aligned in direction 1.
SL
Mark the laser dots A1 and B1 with a pin. Rotate the
SK
instrument by 180° so that it points in the opposite
TR
direction of direction 1. Adjust the instrument so that
BG
Checking the accuracy
RO
B1
B2
max. 2 mm
1.5 m
1
2
A1
A1
1
2
1.5 m
max. 2 mm
B1
B2
the laser beam hits point A1 exactly. If point B2 is no
further than 2 mm away from point B1, then the Leica
Lino is within tolerance.
Should your Leica Lino be outside of the spec-
ified tolerance, please contact an authorised dealer-
ship or Leica Geosystems.