Checking the accuracy of the horizontal line
Set up the instrument on an even and flat surface.
Allow the instrument to level.
Position the instrument approx. 5 m away from the
wall. Direct the instrument at the wall and switch on
the horizontal and front vertical Laser line and mark
the intersection point of laser crosshairs on the wall.
Swivel the instrument to the right and then to the
left. Observe the vertical deviation of the horizontal
line from the marking. If the difference does not
exceed 3 mm, then the Leica Lino is within tolerance.
Leica Lino ML series 785880c en
Checking the accuracy of the vertical line
Set up the instrument on an even and flat surface or
on a stable tripod. Allow the instrument to level. As
reference, use a plumb-bob and attach it as close as
possible to an approx. 3 m high wall. Position the
instrument at a distance of approx. 1.5 m from the
wall at an elevation of approx. 1.5 m. Direct the
instrument at the wall and switch on the laser. Acti-
vate one of the vertical laser lines. Rotate the instru-
ment and align it with the bottom of the plumb line.
Now read off the maximum deviation of the laser line
from the top of the plumb line. If the difference does
not exceed 2 mm, then the Leica Lino is within toler-
ance.