vacon • 32
6.2
Wiring examples
The examples in this chapter show the basic principles for wiring OPTBJ board. Local standards
and regulations should be always followed in the final design.
Example 1: OPTBJ board without reset for Safe Torque Off (STO)
MAIN CIRCUIT
L1
L2
L3
PE
PE
1
3
5
F1
2
4
6
L1
L2
L3
U
V
W
PE
PE
PE
PE
W1
U1
V1
W1
M
3
~
PE
1
2
M1
The figure above shows a connection example of OPTBJ board for Safe Torque Off safety function
without reset. The switch S1 is connected with 4 wires to the OPTBJ board as shown above.
When the switch S1 is activated (contacts open), the drive goes to STO state and motor (if running)
will stop by coasting. If STO fault action is parameterized as "Alarm", the drive indicates: "30 Safe
torque off". Regardless of the parameterization, activation of STO function causes a coasting stop
for motor.
To allow the returning of the drive to ready state without a reset after S1 is deactivated (contacts
closed), STO Fault action must be parameterized as "Alarm". See application manual for related pa-
rameters.
To start the motor operation again, the following sequence is performed.
•
Release the switch S1 (contacts closed). The hardware is now enabled and the drive returns to ready
state.
•
Giving a valid start command starts running the motor.
NOTE! According to EN 60204-1 (Safety of machinery - Electrical equipment of machines), the re-
setting of the emergency stop request (e.g. releasing of emergency stop button) must not restart
the drive.
NOTE! The VACON
command. With the edge-sensitive start command, disactivating the STO does not cause immediate
start.
6
SPEED REFERENCE
CCW
R1
S
CW
W12
1sh
1r
2sh 2p
2s
1
2
3
4
5
6
1
2
3
4
5
6
+10Vref
AI1+
AI1
AI2+
AI2
24Vout
2
STO1+
STO1
STO2+
STO2
RO1 C
7
Installed
X10
1
2
3
4
W10
1r
1b
2r
2b
Safe torque off
11
21
S1
12
22
®
100 default application software uses edge-sensitive start as a default start
START
STOP
S6
S7
13
11
14
12
7
8
9
10
11
12
13
7
8
9
10
11
12
13
GND
DI1
DI2
DI3
CM
24Vout
GND
ON
OFF
RS485
U
I
AO1
U
I
AI2
U
I
AI1
ON
OFF DGND
RO1 NO
TI1+
TI1
OFF
X23
OPTBJ
25
26
28
29
SLOT E
0V
Short circuit and earth
fault protected supply
+24V
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
Commissioning
14
15
16
17
18
19
20
14
15
16
17
18
19
30
A
DI4
DI5
DI6
CM
AO1+
AO/GND
+24Vin
RS485
21
22
B
RS485
Basic I/O
PE
3044B_UK.eps
Need help?
Do you have a question about the optbj and is the answer not in the manual?