Remotec ZTS-110 User Manual page 17

Z-thermostat
Hide thumbs Also See for ZTS-110:
Table of Contents

Advertisement

Functions
Parameter No.
Report filter counter
4 (0x04)
0 (0x0000) to 9999 (0x270F) hours
(read only)
0 (0x00) = C
Scale of temperature
5 (0x05)
1 (0x01) = F (default)
(A) available range:
Unit in Celsius ( C):
Upper limit of set
A = (B+2)min. ~ (37.0 C) max.
6 (0x06)
point (A)
Unit in Fahrenheit ( F):
A = (B+4)min. ~ (99.0 F) max. (default = 99.0 F)
(B) available range:
Unit in Celsius ( C):
Lower limit of set
o
7 (0x07)
5.0 C to 35.0 C
point (B)
Unit in Fahrenheit ( F):
41.0 F to 95.0 F (default = 41.0 F)
o
0 (0x00) = Disable
Easy mode
8 (0x08)
1 (0x01) = Enable, default
0 (0x00) = 24 hours
9 (0x09)
Time format
1 (0x01) = 12 hours (am / pm), default
Value(X): 0 (0x00), 3 (0x03) to 255 (0xFF)
Repeat basic set
0 (0X00) = Disable, default
counter
3 (0x03) to 255 (0xFF) minutes
10 (0x0A)
(Association Group
(Thermostat sends "Basic Set" command to its
A and B only)
association node repeatedly in every X minutes)
0 (0x00) = disable AUTO report if room
temperature is different from last report.
Trigger AUTO report
AUTO report if room temperature is different from
if room temperature
last report.
is different from last
Delta change is >=
report.
1 (0x01) = 1 F (0.5 C)
(It will report room
11 (0x0B)
2 (0x02) = 2 F (1.0 C)
temperature only)
3 (0x03) = 3 F (1.5 C)
4 (0x04) = 4 F (2.0 C), (default)
*User can use this
5 (0x05) = 5 F (2.5 C)
function to enhance
6 (0x06) = 6 F (3.0 C)
batteries service life.
7 (0x07) = 7 F (3.5 C)
8 (0x08) = 8 F (4.0 C)
31
Parameter value range
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Functions
Parameter No.
0 (0x00) = disable AUTO report function.
(by time interval)
AUTO report timer:
1 (0x01) = 0.5 hr
2 (0x02) = 1.0 hr, (default)
3 (0x03) = 1.5 hrs
AUTO report by time
4 (0x04) = 2.0 hrs
interval.
5 (0x05) = 2.5 hrs
(It will report room
6 (0x06) = 3.0 hrs
temperature only)
7 (0x07) = 3.5 hrs
12 (0x0C)
8 (0x08) = 4.0 hrs
*User can use this
9 (0x09) = 4.5 hrs
function to enhance
10 (0x0A) = 5.0 hrs
batteries service life.
11 (0x0B) = 5.5 hrs
12 (0x0C) = 6.0 hrs
13 (0x0D) = 6.5 hrs
14 (0x0E) = 7.0 hrs
15 (0x0F) = 7.5 hrs
16 (0x10) = 8.0 hrs
Temperature offset value.
Formula: Display temperature
= sensor reading value + offset value
(unit = degree F)
0 (0x00) = 0 F (default)
1 (0x01) = 1 F (0.5 C)
2 (0x02) = 2 F (1.0 C)
3 (0x03) = 3 F (1.5 C)
Sensor temperature
4 (0x04) = 4 F (2.0 C)
calibration.
5 (0x05) = 5 F (2.5 C)
(This parameter is
6 (0x06) = 6 F (3.0 C)
used to change the
7 (0x07) = 7 F (3.5 C)
display temperature
8 (0x08) = 8 F (4.0 C)
13 (0x0D)
to match with your
9 (0x09) = 9 F (4.5 C)
previous thermostat,
10 (0x0A) = 10 F (5.0 C)
or to match another
-1 (0xFF) = -1 F (-0.5 C)
thermostat already in
-2 (0xFE) = -2 F (-1.0 C)
your home)
-3 (0xFD) = -3 F (-1.5 C)
-4 (0xFC) = -4 F (-2.0 C)
-5 (0xFB) = -5 F (-2.5 C)
-6 (0xFA) = -6 F (-3.0 C)
-7 (0xF9) = -7 F (-3.5 C)
-8 (0xF8) = -8 F (-4.0 C)
-9 (0xF7) = -9 F (-4.5 C)
-10 (0xF6) = -10 F (-5.0 C)
32
Parameter value range
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o

Advertisement