13.7 Custom Stream Formatting
Each port can be independently configured to stream a default frame format or can be customized to stream a
user-defined format. Custom formatting is very similar to the standard print formatting described in Section 12.0.
Table 13-5 on page 69 lists the format identifiers used to configure a custom print format.
Format Identifier
<P[G I N I T]>
<U[P I S I T]>
<M[G I N I T]>
<S>
<B [–]n,...]
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
Defined By
STR.POS
Polarity. Specifies positive or negative polarity for the current or
STR.NEG
specified (Gross/Net/Tare) weight on the source scale.
STR.PRI
Units. Specifies primary or secondary units for the current or
STR.SEC
specified weight on the source scale.
STR.GROSS
Mode. Specifies gross, net, or tare weight for the current or
STR.NET
specified weight on the source scale.
STR.TARE
STR.MOTION
Status for the source scale. Default values and meanings for each
STR.RANGE
status:
STR.OK
STR.MOTION
STR.INVALID
STR.RANGE
STR.OK
STR.INVALID
See descriptions below
Bit fields. Comma-separated sequence of bit field specifiers. Must
not exceed 8 bits. Entering minus sign before number will negate
the bit setting.
—
Always 0
—
Always 1
Configuration
=1 if even parity
Dynamic
=1 if MODE=NET
Dynamic
=1 if COZ
Dynamic
=1 if standstill
Dynamic
=1 if gross negative
Dynamic
=1 if out of range
Dynamic
=1 if secondary
Dynamic
=1 if tare in system
Dynamic
=1 if tare is keyed
Dynamic
=00 if MODE=GROSS
=01 if MODE=NET
=10 if MODE=TARE
=11 (not used)
Dynamic
=00 if UNITS=PRIMARY
=01 if UNITS=SECONDARY
=10 if UNITS=TERTIARY
=11 (not used)
Configuration
=00 (not used)
=01 if current DSPDIV=1
=10 if current DSPDIV=2
=11 if current DSPDIV=5
Configuration
=00 (not used)
=01 if primary DSPDIV=1
=10 if primary DSPDIV=2
=11 if primary DSPDIV=5
Table 13-5. Custom Stream Format Identifiers
Description
M
In motion
O
Out of range
<space>
OK
I
Invalid
Appendix
69
Need help?
Do you have a question about the 520 and is the answer not in the manual?