Download Print this page

Changes In Configuration Guide Vol. 1 (For Version 2.2) (Ax1240S-S001-30X) - Alaxala AX1250S Series Manual

Software manual corrections for ver. 2.2.c/2.2.d/2.2.e
Hide thumbs Also See for AX1250S Series:

Advertisement

1.
Changes in Configuration Guide Vol. 1 (For Version
2.2) (AX1240S-S001-30X)
3. Switch Capacities
3.2 Switch Capacities
(13) Layer 2 authentication functionality [Change]
The filter conditions that can be specified for the IPv4 access list used for authentication in Table 3-24 Other capacity
limitations regarding Layer 2 authentication – common functionality have been corrected as follows. [Ver. 2.2.E and
later]
Before the change:
Table 3-24 Other capacity limitations regarding Layer 2 authentication-common functionality
Registered general-purpose RADIUS servers
Access list names that can be specified in an authentication-only IPv4 access list
Filter conditions that can be specified in an authentication-only IPv4 access list
Unauthenticated terminals that can be registered
#1
This is the number of registered general-purpose RADIUS servers in the whole Switch, including login
security functionality.
#2
If you set a number of filter entries that exceeds the Switch capacity, only the entries within the capacity
limitations are applied.
#3
When the number of unauthenticated terminals exceeds the maximum number, delete those with older update
periods and register newly unauthenticated terminals.
After the change:
Table 3-24 Other capacity limitations regarding Layer 2 authentication-common functionality
Registered general-purpose RADIUS servers
Access list names that can be specified in an authentication-only IPv4 access list
Filter conditions that can be specified in an authentication-only IPv4 access list
Unauthenticated terminals that can be registered
#1
This is the number of registered general-purpose RADIUS servers in the whole Switch, including login
security functionality.
#2
If you set a number of filter entries that exceeds the Switch capacity, only the entries within the capacity
limitations are applied.
#3
When the number of unauthenticated terminals exceeds the maximum number, delete those with older update
periods and register newly unauthenticated terminals.
Item
Item
5
AX1240S-AP-0202C_R2X
Maximum number
#1
20
1
#2
20
#3
256
Maximum number
#1
20
1
#2
250
#3
256

Advertisement

loading

This manual is also suitable for:

Ax1240s series