AX1240S-AP-0202C_R2X
(2) schedule-power-control port cool-standby [Change]
The impact on communication and the notes have been corrected as follows. [Ver. 2.2.E and later]
Before the change:
Impact on communication:
None
Notes:
1. If this command is set, link-up of the Fast Ethernet port takes about 3 seconds.
After the change:
Impact on communication:
Yes
Notes:
1. If this command is set, link-up of the Fast Ethernet port takes about 3 seconds.
2. If this command is set, the link status of all the Fast Ethernet ports changes, which affects
communication.
3. The power saving functionality is disabled for Fast Ethernet ports with the speed fixed setting or
automatic MDIX functionality disabled. To enable the port power saving functionality, disable
auto-negotiation and enable the automatic MDIX functionality (
4. With the scheduled port power saving functionality enabled, at the scheduled time the link status of the
Fast Ethernet ports changes in the same way as when using the
command.
If you do not want the link status to change at the scheduled time due to the port power saving
functionality, also set the
32. SNMP
(1) snmp-server host [Change]
Table 32-2 Correspondence between parameters and traps has been corrected as follows:
Before the change:
Table 32-2 Correspondence between parameters and traps
snmp
rmon
temperature
air-fan
login
power-control port cool-standby
Parameter
mdix auto
power-control port cool-standby
Trap
cold Start
warm Start
link Up
link Down
authentication Failure
risingAlarm
fallingAlarm
ax1240s TemperatureTrap
ax1240s AirFanStopTrap
ax1240s LoginSuccessTrap