Multi-Sense
Multi-Configurable, Wet-to-Wet Differential Pressure Transducer
REMOTE SENSOR
DIMENSIONS
Transducer w/Conduit (3M)
1/2 inch Conduit Opening
91.78
3.61
19.4
.76
1/4" NPT MALE
Transducer w/Hirschmann
Connector (AJ)
7.3
.29
31.8
1.25
19.4
.76
Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
Model 231RS
®
Electrical Data (Voltage)
Circuit
Excitation
Output
1
Output Impedance
Circuit Consumption
Electrical Data (Current)
Circuit
Output
2
External Load
1/2" CONDUIT
COVER
Min. Supply Voltage
Max. Supply Voltage
Physical Description
Case
Pressure Fittings
Electrical Connection
41.07
1.617
Size
Weight
Environmental Data
Operating
Temperature
°F (°C)
3
Storage Temperature
°F (°C)
Vibration
Shock
HIRSCHMAN CONNECTOR
41.07
1.617
1/4" NPT MALE
Performance Data
3-Wire
Accuracy RSS
15 to 30 VDC/18 to 30 VAC
(Reverse
6
Pressure Ranges A, B, C
Excitation Protected)
0 to 5 VDC, 0 to 10 VDC, 1 to 5 VDC
Pressure Ranges D
30 Ohms
Pressure Ranges (Selection Example, Pg 4.)
Range Code
8 mA (typ.) at 5 VDC, 8 mA (typ) at 10
VDC, 40 mA (typ.) at 18-30 VAC
RS1
RS2
2-wire (Reverse Excitation Protected)
RS3
4 to 20 mA
RS4
0 to 250 Ohms
RS5
15 VDC + 0.02 x Resistance of receiver
Pressure Media
plus line)
30 VDC + 0.004 x Resistance of receiver
Liquids or Gases Compatible with 17-4 PH Stainless Steel
plus line)
Note: Hydrogen not recommended for use with 17-4 PH stainless steel
Thermal Effects
Die Cast Aluminum, Powder Coated
Compensated Range
Zero/Span Shift
1/4-18 NPT Male
(50°C)
1/2 in. Conduit
Warm-up Shift
4.0 x 6 x 2 in. (102 x 152 x 51 mm)
Response Time
1.3 lb
Proof Pressure
Burst Pressure
-4 to +185 (-20 to -85)
1
Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
2
Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.
-4 to +185 (-20 to +85)
3
Operating temperature limits of the electronics only. Pressure media temperatures may be
considerably higher or lower.
10g from 50Hz to 2000 Hz
RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
4
Units calibrated at nominal 70˚F. Maximum thermal error computed from this datum.
5
200g
Specifications subject to change without notice.
6
NOT RECOMMENDED TO CONNECT VAC EXCITATION TO EARTH (SAFETY) GROUND
Transducer w/Packard
Connector (4M)
3 PIN PACKKARD
CONNECTOR
GENERAL SPECIFICATIONS
(at constant temp.)
4
±1.0% FS
±2.0% FS
A
B
C
D
50
25
10
5
75
37.5
15
7.5
100
50
20
10
150
75
30
15
250
125
50
25
5
°F (°C)
+32 to +130 (0 to +54)
%FS/100°F
2.0 (1.8)
<0.12% FS
1 to 5 sec. (selectable)
2 x Full Scale
15 x Full Scale (50 psi), 10 x Full Scale
(75 x 150 psi), 8 x Full Scale (250 PSI)
79.2
3.12
19.4
.76
Max. Line
Pressure
50
75
100
150
250
Need help?
Do you have a question about the Multi-Sense 231RS and is the answer not in the manual?