354 – AL Open Load Cylinder B4
Yellow alarm; warning
Cause
Open circuit in cylinder B4
injector wiring. Result: Misfiring.
355 – AL Open Load Cylinder B5
Yellow alarm; warning
Cause
Open circuit in cylinder B5
injector wiring. Result: Misfiring.
356 – AL Open Load Cylinder B6
Yellow alarm; warning
Cause
Open circuit in cylinder B6
injector wiring. Result: Misfiring.
357 – AL Open Load Cylinder B7
Yellow alarm; warning
Cause
Open circuit in cylinder B7
injector wiring. Result: Misfiring.
358 – AL Open Load Cylinder B8
Yellow alarm; warning
Cause
Open circuit in cylinder B8
injector wiring. Result: Misfiring.
359 – AL Open Load Cylinder B9
Yellow alarm; warning
Cause
Open circuit in cylinder B9
injector wiring. Result: Misfiring.
Corrective action
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
exchanging injectors).
2. Fault is rectified after each working cycle.
Corrective action
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
exchanging injectors).
2. Fault is rectified after each working cycle.
Corrective action
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
exchanging injectors).
2. Fault is rectified after each working cycle.
Corrective action
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
exchanging injectors).
2. Fault is rectified after each working cycle.
Corrective action
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
exchanging injectors).
2. Fault is rectified after each working cycle.
Corrective action
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
exchanging injectors).
2. Fault is rectified after each working cycle.
MS15054/03E 2018-07 | Troubleshooting | 97