7-3-2.

Flags (D046h)

MSB
Address
D7
D046h
Write
None
Access
Default
SV – Supply Voltage (VDD) Flag
0 = Supply voltage is within specification.
1 = Supply voltage is outside of specification.
HV1 – Heater Voltage Flag
0 = Heater voltage is within specification.
1 = Heater voltage is outside of specification.
OS1 – Open Sensor Flag
0 = Sensor is connected.
1 = Sensor is not connected.
HV2 and OS2 are reserved bits. In case of write access, you should set to "0".
*
If you want to read flag register, it is recommended to read twice in order to avoid conflict with the
MCU update.
D6F-PH MEMS Differential pressure Sensor User's Manual (A288)
Table11. FLAGS
D6
D5
None
None
D4
D3
OS1
Host &
None
MCU
0
0
D2
D1
HV1
Host &
None
MCU
0
0
LSB
D0
SV
Host &
MCU
0
14