Specification - ABB Navigator 540 Instruction Manual

Measurement made easy
Hide thumbs Also See for Navigator 540:
Table of Contents

Advertisement

Symbols
Symbols that appear on this product are shown below:
Functional earth (ground) terminal.
Protective earth.
Alternating current supply only.
This symbol, when noted on a product, indicates a potential hazard which could cause serious personal injury and / or death.
The user should reference this instruction manual for operation and / or safety information.
This symbol, when noted on a product enclosure or barrier, indicates that a risk of electrical shock and / or electrocution exists
and indicates that only individuals qualified to work with hazardous voltages should open the enclosure or remove the barrier.
Recycle separately from general waste under the WEEE directive
Product recycling and disposal (Europe only)
Electrical equipment marked with this symbol may not be disposed of in European public disposal systems after 12 August
2005. To conform to European local and national regulations (EU Directive 2002/96/EC), European electrical equipment users
must now return old or end-of-life equipment to the manufacturer for disposal at no charge to the user.
ABB is committed to ensuring that the risk of any environmental damage or pollution caused by any of its products is minimized
as far as possible.
Note. For return for recycling, please contact the equipment manufacturer or supplier for instructions on how to return end-of-life
equipment for proper disposal.
Restriction of Hazardous Substances (RoHS)
The European Union RoHS Directive and subsequent regulations introduced in member states and other countries limits the
use of six hazardous substances used in the manufacturing of electrical and electronic equipment. Currently, monitoring and
control instruments do not fall within the scope of the RoHS Directive, however ABB has taken the decision to adopt the
recommendations in the Directive as the target for all future product design and component purchasing.

Specification

Electrical
Power supply ranges
100 to 240 V AC max., 50 / 60 Hz ± 10 %
(90 to 264 V AC, 45/65 Hz)
Power consumption
<10W
Terminal connections rating
AWG 26 to 16 (0.14 to 1.5 mm
Analog outputs
2 standard
2 optional
Galvanically isolated from the rest of the circuitry, 500 V for 1
minute. Range-programmable source and range 0 to 22 mA,
maximum load 750  @ 20 mA.
CI/AWT540–EN Rev. C
2
)
Relay outputs
4 standard
2 optional
Fully-programmable. Contacts rated at 5A @ 110 / 240 V. Standard
relays are changeover. Optional relays are normally closed (N/C).
Digital inputs / outputs
6 standard, user-programmable as input or output.
Minimum input pulse duration: 125 mS.
Input – volt-free or 24 V DC (conforms to IEC 61131-2).
Output – open-collector, 30 V, 100 mA max.
(conforms to IEC 61131-2).
3